Inc Sound Module Decoder - Manual

© 2017 Digitrax, Inc.
www.digitrax.com- 59 -
TABLE XII: FX
3
Operational Characteristics Table
Value to Add for
CV Value Com-
putation for FX
3
How the FX
3
Effect Generated Will Operate
0 Forward direction, ON with function ON, eect phase A*
16 Reverse direction, ON with function ON, eect phase B*
32 Non directional eect, ON with function ON, eect
phase A*
48* Non directional eect, ON with function ON, eect
phase B*
64* Forward direction, ON with F0 ON & function ON, ef-
fect phase A*
80* Forward direction, ON with F0 ON & function ON, ef-
fect phase B*
96* Special logic for Forward Ditch Light or Rule 17 dim-
ming, standard Ditch Light Operation
112 Special logic or Reverse Ditch Light or Rule 17 dimming ,
standard Ditch Light Operation
160 Speed=0, non directional eect, phase A and function
qualier
176 Speed>0, non directional eect, phase B and function
qualier
192* Ditch light o phase A Alternate Ditch light operation-
OFF when running ash on with F2
208* Ditch light o phase B Alternate Ditch light operation-
OFF when running ash on with F2
*Master Light
Switch
To use F0 as the Master Light Switch, you must use 48,
64, 80, 96, 192, or 208
*Each FX
3
function can be set up to have two phases. This allows you to set
up ditch lights and other effects where you use two function leads that alter-
nate. Each of two function outputs is wired to a different LED/Lamp and
Phase A & B are set up to have them alternate being on.
9.5 FX
3
Rate & Keep Alive Brightness CV62
CV62 controls the keep alive/baseline off voltage for incandescent lamps. This
lets you set a lamp so that it does not go completely off for a realistic simula-
tion of ditch lights. LEDs behave differently than lamps so this adjustment
should be set to 0.