Inc LocoNet Cable Maker Kit - Manual

© 2020 Digitrax, Inc. www.digitrax.com— 5 —
data, amplify or boost the signal and output it to the track. RailSync can
also be used as a source of power for low current devices such as throt-
tles.
The LocoNet data network capability can run on as few as 2 or 3 wires.
Confusion may result in that the whole cable is termed a “LocoNet” cable
but in fact carries the LocoNet data messages and also packet copy/con-
nectivity functions.
Digitrax uses the following LocoNet Wiring Convention:
Pin No Color Function Voltage
1 White
Black
Red
Green
Yellow
Blue
Rail Sync B
Ground
LocoNet
LocoNet
Ground
Rail Sync A
7 vdc
14.5 vdc
14.5 vdc
7 vdc
2
3
4
5
6
All components are RJ12 6-wire
Do not use RJ11 4-wire
Male Plug
Female Jack
1 2 3 4 5 6
6 5 4 3 2 1
6 5 4 3 2 1
Rail Sync
Rail Sync
Ground
LocoNet
LocoNet
Ground
Rail Sync
Rail Sync
Ground
LocoNet
LocoNet
Ground
This arrangement is called a data cable.
LocoNet Wiring: The Theory Behind the Practice
Digitrax recommends using the 6-wire conguration for the following
reasons:
1. In a 6 wire at conguration, the left 3 wires are eectively a “mir-
ror” image of the right 3 wires.
2. There are 2 Ground (pins 2 & 5) and 2 LocoNet data connections
(pins 3 & 4), so the eective “loop resistance” is lower because of
paralleled wires. This lets LocoNet run over greater distances.
3. If one ground or signal connection is broken or intermittent, the
network can maintain a reliable connection.