Specifications

Technical Specifications
Supported RS232 DTE Signals:
Function
Abbreviation
PIN1 N/A
PIN2 Received Data Rx
PIN3 Transmit Data Tx
PIN4 Data Terminal Ready DTR
PIN5 Signal Ground GND
PIN6 Data Set Ready DSR
PIN7 Request To Send RTS
PIN8 Clear To Send CTS
PIN9 N/A
Additional Options
When distances over 150M, we suggest to use a unit for
picture calibration (as shown below).
(Item No: DC-59100)
Troubleshooting
1. If the Power LED of Remote is not on, please make
sure power adapter is connected to Remote.
2. If no video signal is displayed on the monitor.
(1) Please check all of VGA cable and CAT.5 cable
is loosened or disconnected.
(2) Power adapter is not connected.
3. If video signal is foggy or un-clear, please check VGA
connector, or low the VGA resolution for long cable. It
is highly recommended to use “optimal CAT.5 cable
length” to get the best video quality and not to waste
unnecessary CAT.5 cable.
4. If RS232 communication does not work smoothly,
check the baud rate setting of two ends, they must be
consistent.
-3-
Trademarks:
All the companies, brand names, and product names
referred to this manual are the trademarks or registered
trademarks belonging to their respective companies.
-4-