Bench Shipping Scale DWP-440 DWP-800 DWP-1100 DWP-102E Indicator User Manual A12-51007 V1.
Main Specification 1. Model: DWP-440 bench shipping/counting scale 2. Accuracy: GradeⅢ, n=3000 3. Sample Rate: 10 times / second 4. Load cell sensitivity: 1.5~3mV / V 5. Scale interval: 1/2/5/10/20/50 for option 6. Display: 6 bits LCD,6 state indicating signals 7. Scoreboard interface (optional): In serial output mode:current loop signal, transmission distance≤50m, 8. Communication interface (optional):RS232C;Baud rate 1200/2400/4800/9600 optional 9. Power supply: -1- Battery DC6V/4AH 10.
SECTION 1 INTRODUCTIONS 1.1 Introduction The indicator provides an accurate, fast and versatile series of general purpose weighing indicator with counting, check-weighing, animal weighing functions and preset tare. 1.2 Specification plastic housing Housing 110V 50/60Hz Power supply built-in rechargeable battery.
3) Move the cursor to change the digit when setting parameters or other functions. TARE Key 1) When self-checking, Press TARE Key to enter fast calibration; 2) Tare the scale. Store the current weight in memory as a tare value, subtract the tare value from the weight and shows the net weight. Entering a value using the keypad will store that value as the tare value; 3) Cycle through the functions or increase the active digit when setting value for parameters or other functions.
The scale has an automatic re-zeroing function to account for minor drifting or accumulation of material on the platform. However you may need to press ZERO Key to re-zero the scale if small amounts of weight are shown when the platform is empty. 3.4 Tare the scale When a container is applied it needs to tare off and obtains a net weight. Remove all weights from the platform and make the platform empty. Make sure that the ZERO indicator is on.
cancel hold function. 3.8 Presetting tare value (KEY=4) Press MOD Key to preset tare value. While every weighing, the value displayed is the one actual weight substrate the preset tare value. 3.9 Animal weighing (Key=5) Press MOD Key to set parameters of animal weighing. 1) Stable time “Fil n”. Options: 1/2/3/4/5. 1 is the fastest and 5 is lowest. The longer of stable time, the harder to lock. 2) Display range “Rang n”. Options: 1/2/3. Option 2 is recommended. 3) Leaving lock range.
SLP no: Set to “SLP no” means the indicator will never sleep. SLP 3: Set the time span 3 minutes for the sleep. This sleep mode has two options: “off & dot”, which can be selected by pressing FUN Key when displaying “SLP 3” . ”off” means cutting off the power and “dot” means only a dot at the last digit will be displayed. When “dot”, weight changing can wake up the indicator. SLP 5/10/15: Same as SLP 3.
SECTION 5 RS-232 OUTPUT Specifications: RS-232 output of weighing data, 1200/2400/4800/9600/19200 bps,1 stop bit, 8 data bits, No Parity. Mode 1: Continue output ST,GS 0.119,kg ST for stable; US for unstable ; GS for gross weight; NT for net weight ; 0.119 for weighing value; kg for unit (kg, lb); HEX 0d and HEX oa : HEX for hex; 0d for enter; 0a for next line. Mode 2: Automatic output Automatic output mode is same as continue output.