Owner’s Manual Model XLF50 XLF74 XLF100 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this fireplace. For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage. To view the full line of Dimplex products, please visit www.dimplex.
Table of Contents Welcome & Congratulations . . . . . . . . . . . . . . . . . . . . . . . 3 IMPORTANT INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . 4 Quick Reference Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Fireplace Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 For Bathroom Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Final Assembly . . . .
Welcome & Congratulations Thank you and congratulations for purchasing an electric fireplace from Dimplex. Please use our convenient online registration page to record your model and serial numbers for future reference at www.dimplex.com/register Model and Serial Number Label Please carefully read and save these instructions. CAUTION: Read all instructions and warnings carefully before starting installation.
IMPORTANT INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: ⑥ Do not operate the unit after it malfunctions. Disconnect power at the service panel and contact ① Read all instructions before installing or using this electric fireplace. ⑦ Do not use outdoors. ② This fireplace is hot when in use. To avoid burns, do not let bare skin touch hot surfaces.
IMPORTANT INSTRUCTIONS ⑭ Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons. WARNING: Remote control contains small batteries. Keep away from children. If swallowed, seek medical attention immediately. ⑮ Do not burn wood or other materials in the electric fireplace.
Quick Reference Guide 1. The electrical information regarding your electric fireplace can be found on the rating label located on the top of the unit. Please use our convenient online registration page to record your model and serial numbers for future reference at www.dimplex.com/register 2. If you have any technical questions or concerns regarding the operation of your electric fireplace, or require service contact customer service at 1-888-346-7539. 3.
Fireplace Installation glass and partially reflective CAUTION: Ensure installation glass, safely, in the box until does not allow fireplace to be in the time you are ready to direct contact with building vapor install it. barrier or insulation and meets all local building code. 3. Store the fireplace in a safe, dry and dust free location until ! NOTE: A dedicated, properly you are ready to install the fused 15 Amp circuit is refireplace. quired, rated for the appropriate voltage (120V, 240V).
Fireplace Installation to ½ in. (10 mm) to ensure adequate air flow of heated air out of the firebox area. 1. Prepare a wall with a framed opening of 16 in. (40.6 cm) high, • XLF50 - 50 ⅝ in. (128.7 cm) • XLF74 - 74 ⅝ in. (189.7 cm) • XLF100 - 100 ⅝ in. (255.7 cm) wide, with a bottom sill that is a minimum of 3.5 in. (9.0 cm) deep (figure 2).
Fireplace Installation Figure 4 Flame Panel Mounting Holes required. 6. Drive four supplied mounting screws through the four mounting holes located on the inside surface of the fireplace chassis, into wall studs (Figure 4). 120V Installation - Direct Wire ! NOTE: The unit is designed to be hardwired to a power source and should not have a cord installed to allow the unit to be plugged into a wall receptacle.
Fireplace Installation • Continue to the final assembly instructions. 120V Installation - Wall Switch ! NOTE: Use a single pole, FIREPLACE JUNCTION BOX single throw (On/Off) wall switch that is rated for a minimum of 15 amps. ! NOTE: The unit is designed to be hardwired to a power source and should not have a cord installed to allow the unit to be plugged into a wall receptacle. Use two conductor, non-metallic sheath cable with ground wire (3 wires total) for the incoming power supply.
Fireplace Installation Figure 6 Retaining Bracket Glass Openings Partially Reflective Glass cure and do not protrude past the flame panel, so as not to be visible after final assembly. • Continue to the final assembly instructions. 240V Installations Use three conductor, non-metallic sheath cable with ground wire (4 wires total) for the incoming power supply on fireplace inserts. CAUTION: Use the appropriate wire to meet local and national electrical codes for rated power consumption.
Fireplace Installation For Bathroom Use If this unit is installed in a bathroom it must be protected by a GFI receptacle or circuit. If receptacle is used it must be readily accessible. To prevent electrical shock this unit is an electrical appliance that is NOT watertight and must be installed as to prevent water from entering unit. This must be installed away from showers, tubs, etc. Never locate fireplace where it may fall into a bathtub or other water container. Final Assembly 1.
Fireplace Installation Figure 7 Wiring Diagram XLF50 CERAMIC ELEMENT MAIN CONTROL BOARD FAN THERMAL CUTOUTS FAN THERMISTOR M POWER ADAPTER FLICKER MOTOR FLAME LED ASSEMBLY MEDIA LED ASSEMBLY MEDIA LED ASSEMBLY XLF74, XLF100 CERAMIC ELEMENT MAIN CONTROL BOARD FAN THERMAL CUTOUTS FAN THERMISTOR M POWER ADAPTER FLICKER MOTOR RELAY BOARD POWER ADAPTER FLAME LED ASSEMBLY MEDIA LED ASSEMBLY MEDIA LED ASSEMBLY 13
Operation General Operation WARNING: This electric firebox must be properly installed before it is used. This firebox operates with Comfort$averTM technology, which automatically adjusts the fan speed and heater wattage to safely and precisely match the requirements of the room based on the thermostat setting. The heater operates such that once the room reaches the set point, the fan and heater will continuously run at a low level, to maintain the desired room temperature.
Operation Figure 8 Figure 9 C J Display A C D E H I A B C D F E G H I J → Activated by pressing the button on the remote. C. Heat ON/OFF Turns the heater On and Off. → Activated by pressing the button on the remote or the unit. • Indicated by the icon and the setpoint temperature will flash on the display, then the intake temperature will be displayed before turning off.
Operation room.** E. • Indicated by the Display and a reduced fan speed. Temperature Up Increases the temperature setting. → Adjusted by repeatedly pressing the corresponding button on the remote.* • Indicated by the setpoint on the Display increasing and the speed of the fan increasing to increase the amount of heat being projected into the room. * The first time the button is pressed the current temperature set point will be displayed for 2 seconds.
Operation H. Color Themes Different presets of lighting color combinations are available in the unit. → Changed by repeatedly pressing the corresponding button on the remote or the unit. • Cycles through the different preset light settings of the unit, this includes different combinations of colors of the flame base and media lighting. ! NOTE: Two of the themes in the cycle are a prism where the unit cycles through a variety of colors.
Operation ing the unit back on. CAUTION: If you need to continuously reset the heater, turn the unit off at the main disconnect panel and call technical support at 1-888-346-7539. Remote Control Battery Replacement To replace the Battery: 1. Slide battery cover open on the remote control. 2. Correctly install one 3 Volt (CR2032 [longer life] or CR2025) Battery in the battery holder. 3. Close the battery cover. Battery must be recycled or disposed of properly.
Maintenance WARNING: Disconnect power and allow heater to cool before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons. ! NOTE: The fireplace should not be operated with an accumulation of dust or dirt on or in the unit, as this can cause a build up of heat and eventual damage. For this reason the heater must be inspected regularly, depending upon conditions and at a minimum yearly intervals. not use abrasive cleaners.
Warranty Products to which this limited warranty applies This limited warranty applies to your newly purchased Dimplex electric fireplace. This limited warranty applies only to purchases made in any province of Canada except for Yukon Territory, Nunavut, or Northwest Territories or in any of the 50 States of the USA (and the District of Columbia) except for Hawaii and Alaska. This limited warranty applies to the original purchaser of the product only and is not transferable.
Warranty not commercially practicable or cannot be timely made, Dimplex may, in lieu of repair or replacement, choose to refund the purchase price for such product or part. • Limited warranty service will be performed solely by dealers or service agents of Dimplex authorized to provide limited warranty services. • For products other than surrounds (mantels) and trims, this 2 year limited warranty entitles the purchaser to on-site or in-home warranty services.
Technical Support Technical and troubleshooting support, as well as a list of replacement parts can be found on www.dimplex.com/customer_support. Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N3H 4W3 © 2017 Dimplex North America Limited 22 www.dimplex.