User Manual

8 www.dimplex.com
Fireplace Installation
to ½ in. (10 mm) to ensure
adequate air ow of heated air
out of the rebox area.
1. Prepare a wall with a framed
opening of 16 in. (40.6 cm)
high,
XLF50 - 50 ⅝ in. (128.7 cm)
XLF74 - 74 ⅝ in. (189.7 cm)
XLF100 - 100 ⅝ in. (255.7 cm)
wide, with a bottom sill that is
a minimum of 3.5 in. (9.0 cm)
deep (gure 2). The sill can
be constructed to support the
front of the unit to allow the
power supply wires to easily
be run behind or ush with the
back of the unit and a pass
thru hole drilled for electrical
wire routing.
!
NOTE: It is recommended that
the bottom of the unit be mounted
between 30 in. (76.2 cm) and 40
in. (102 cm) from the ground to
maintain an optimized viewing
angle of the ame.
WARNING: Do not attempt
to wire your own new circuits. To
reduce the risk of re, electric shock
or injury to persons, always use a
licensed electrician.
WARNING: Ensure that the
circuit on which the replace is to
be installed has the power cut off
at the service panel until installa-
tion is complete.
2. The unit is provided with an
installed ¾ in. (2.0 cm) trim.
Depending on the installation,
this trim can be removed by
removing the securing screws
and the 4 trim pieces.
3. Ensuring a minimum of 18 in.
(46.7 cm) of slack, route the
supply power wire through a
cable clamp (not included) and
in the opening in the back of
the unit. (Figure 3)
4. Lift replace, from the bottom
and the handles located on the
back, and insert into opening
to the desired depth.
5. Using a bubble level (supplied)
ensure that the replace is level
within the framing. Adjust as
Figure 3
Grounding
Screw
Cable Clamp