Installation manual

32
4.3.3 D
EFROST
Before running a manual defrost cycle you must ensure the buffer has been isolated from the heating, as stated by the
message on the UI. Selecting ‘Start Defrost’ begins the defrost cycle. The defrost screen will state the time remaining in
the defrost cycle.
A heating water return temperature of 18°C is required for proper defrosting of the evaporator.
4.3.4 O
PERATING
DATA
The operating data menu provides a list of all the system parameters, such as all temperatures, including each zone set
and actual temperatures, flow rate, and heat pump status. If an SD card is present, this data will be recorded to every
message listed.
4.3.5 H
ISTORY
The History menu shows the temporary and permanent run time history of the system. These values can be reset in
order to record run times over a certain time period. Selecting ‘Next’ brings you to the permanent run time history which
cannot be reset unless a software update is installed.
4.3.6 S
ERVICE
M
ENU
The service menu can be accessed, in a similar manner to the installation menu, by inputting the installer menu code
(22) and then using the ’Login’ access code 998. Access to this menu may be required for fault finding or
servicing.
NOTE: T
HIS
FUNCTION
MUST
ONLY
BE
USED
WITH
GREAT
CARE
BY
TRAINED
INSTALLERS
,
AS
THE
CONDENSER
PLATE
HEAT
EXCHANGER
MAY
POTENTIALLY
FREEZE
IF
THE
WATER
FLOW
TEMPERATURE
IS
TOO
LOW
. T
HIS
FUNCTION
HAS
THE
POTENTIAL
TO
FREEZE
THE
CONDENSER
(F43-47
ERROR
MESSAGES
ARE
DEFROST
ERRORS
).