TABLE OF CONTENTS OPERATION PAGE 1 VOLTAGE SELECTOR SWITCH LOCATION PAGE 3 PARTS LIST DRAWING PAGE 4 PARTS LIST PAGE 5 WIRING DIAGRAM – LOWER SECTION PAGE 7 WIRING DIAGRAM – UPPER SECTION PAGE 8 WIRING DIAGRAM – SCHEMATIC PAGE 9 LIGHT BULB REPLACEMENT PAGE 10 MAIN ON/OFF SWITCH REPLACEMENT PAGE 11 HEATER ON/OFF SWITCH REPLACEMENT PAGE 12 FLAME MOTOR/FLAME ROD REPLACEMENT PAGE 13 VOLTAGE SELECTOR SWITCH REPLACEMENT (UNIT IS PERMENANTLY INSTALLED IN WALL) BF33ST, BF33DX BF39ST, BF39DX, B
BLOWER MOTOR/BLOWER REPLACEMENT (UNIT CAN BE REMOVED FROM WALL) PAGE 25 TEMPERATURE LIMIT SWITCH REPLACEMENT (UNIT IS PERMENANTLY INSTALLED IN WALL) BF33ST, BF33DX BF39ST, BF39DX, BF45ST, BF45DX PAGE 26 PAGE 28 TEMPERATURE LIMIT SWITCH REPLACEMENT (UNIT CAN BE REMOVED FROM WALL) PAGE 30 REMOTE CONTROL KIT REPLACEMENT PAGE 31
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX OPERATION MANUAL CONTROLS (WITHOUT REMOTE OPTION) The fireplace can be controlled by the manual switches located on the fireplace (FIGURE 1). Main Power Switch Main ON/OFF switch, activates the flame effect. Heater Control Switch Heater ON/OFF switch, activates heater to the high level.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX REMOTE CONTROL The remote control has a range of approximately 50ft. (15.25m). It does not have to be pointed at the fireplace and can pass through most obstacles (including walls). It is supplied with one of 243 independent frequencies to prevent interference with other units. The frequency designation is indicated on the back of the transmitter (FIGURE 3).
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX RESETTING THE TEMPERTURE CUTOUT SWITCH The heater on this fireplace is protected with a safety device to prevent overheating. Should the heater overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the Main Power switch (FIGURE 1) to OFF and waiting 5 minutes before switching it to ON. WALL MOUNTED CONTROLS The fireplace can be installed with wall mounted controls.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX 8 7 5 6 9 12 11 13 10 15 3 14 1 2 4 16 17 18 4
BF33ST, BF33DX, BF39ST, BF39DX REPLACEMENT PARTS DIMPLEX BUILT IN FIREPLACE REPLACEMENT PART 1. LOG SET 2. REFLECTOR ROD 3. GROMMET 4. FLICKER ASSEMBLY 5. BLOWER ASSEMBLY 6. BLOWER MOTOR 7. HEATER ELEMENT 8. CUTOUT 9. VOLTAGE SELECTOR 10. MAIN ON/OFF SWITCH 11. HEATER SWITCH 12. MIRROR SEMI-SILVERED 13. EXTRUSION 14. STEEL CURTAIN 15. STEEL CURTAIN ROD 16.
BF45ST, BF45DX REPLACEMENT PARTS DIMPLEX BUILT IN FIREPLACE REPLACEMENT PART 1. LOG SET 2. REFLECTOR ROD 3. GROMMET 4. FLICKER ASSEMBLY 5. BLOWER ASSEMBLY 6. BLOWER MOTOR 7. HEATER ELEMENT 8. CUTOUT 9. VOLTAGE SELECTOR 10. MAIN ON/OFF SWITCH 11. HEATER SWITCH 12. MIRROR SEMI-SILVERED 13. EXTRUSION 14. STEEL CURTAIN 15. STEEL CURTAIN ROD 16.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX WIRING DIAGRAM - LOWER SECTION WHITE BLUE 1A 5B 2A G 4B GREEN RED (L2) BLACK (L1) WHITE (N) TWIST-TIE 2 HEATER SWITCH 1 BYPASS HARNESS RED BLACK (L1) BROWN FROM TOP RED FROM TOP WHITE (N) ORANGE FROM TOP RED RED (L2) LOWER HARNESS BLACK MAIN SWITCH MARR WHITE 7 RED (2) RED (1) BLUE (4) MARR BLUE (3) WHITE CAPACITOR WHITE BLACK FLICKER MOTOR BROWN BLACK
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX WIRING DIAGRAM - UPPER SECTION BROWN ORANGE RED (CUT-OUT LONG WIRE) BLK 5 3 1 6 4 2 YLW BLK BLW.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX WIRING DIAGRAM - SCHEMATIC 9
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. Light bulbs need to be replaced when you notice a dark section of the flame. There are four bulbs under the log set which generate the flames and embers.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE MAIN ON/OFF SWITCH 1. Open the steel curtains (remove glass doors if applicable). 2. Remove the log grate retaining screws and remove the log grate. 3.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HEATER ON/OFF SWITCH (without remote control option) NOTE: Remote control kit does not have individual heater switch.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE FLAME MOTOR/FLAME ROD 1. Open the steel curtains (remove glass doors if applicable). 2. Remove the log grate retaining screws and remove the log grate. 3.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons.
BF33ST, BF33DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE VOLTAGE SELECTOR SWITCH (UNIT IS PERMENANTLY INSTALLED IN WALL) 1. Remove the log grate retaining screws and remove the log grate. 2.
BF33ST, BF33DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE VOLTAGE SELECTOR SWITCH (UNIT IS PERMENANTLY INSTALLED IN WALL) 14. Properly orientate the new switch and connect all of the wiring connections to the heater elements.
BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE VOLTAGE SELECTOR SWITCH (UNIT IS PERMENANTLY INSTALLED IN WALL) 1. Remove the log grate retaining screws and remove the log grate. 2.
BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE VOLTAGE SELECTOR SWITCH (UNIT IS PERMENANTLY INSTALLED IN WALL) 12. Use (2) wire connectors to connect the 4 stripped wires with matching colour.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE VOLTAGE SELECTOR SWITCH (UNIT CAN BE REMOVED FROM WALL) 1. Remove unit from installed wall. (remove trim surround if applicable) 2.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HEATING ELEMENTS (UNIT IS PERMENANTLY INSTALLED IN WALL) NOTE: The fireplace is equipped with two heating elements.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HEATING ELEMENTS (UNIT CAN BE REMOVED FROM WALL) NOTE: The fireplace is equipped with two heating elements.
BF33ST, BF33DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE BLOWER MOTOR / BLOWER (UNIT IS PERMENANTLY INSTALLED IN WALL) 1. Remove the log grate retaining screws and remove the log grate. 2.
BF33ST, BF33DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE BLOWER MOTOR / BLOWER (UNIT IS PERMENANTLY INSTALLED IN WALL) 14. Reassemble in the reverse order as above.
BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE BLOWER MOTOR / BLOWER (UNIT IS PERMENANTLY INSTALLED IN WALL) 1. Remove the log grate retaining screws and remove the log grate. 2.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE BLOWER MOTOR / BLOWER (UNIT CAN BE REMOVED FROM WALL) 1. Remove unit from installed wall. (remove trim surround if applicable) 2.
BF33ST, BF33DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE TEMPERATURE LIMIT SWITCH (UNIT IS PERMENANTLY INSTALLED IN WALL) 1. Remove the log grate retaining screws and remove the log grate. 2.
BF33ST, BF33DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE TEMPERATURE LIMIT SWITCH (UNIT IS PERMENANTLY INSTALLED IN WALL) 14.
BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE TEMPERATURE LIMIT SWITCH (UNIT IS PERMENANTLY INSTALLED IN WALL) 1. Remove the log grate retaining screws and remove the log grate. 2.
BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE TEMPERATURE LIMIT SWITCH (UNIT CAN BE REMOVED FROM WALL) 1. Remove unit from installed wall. (remove trim surround if applicable) 2.
BF33ST, BF33DX, BF39ST, BF39DX, BF45ST, BF45DX If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to avoid accidental burning of skin. Disconnect circuit power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE REMOTE CONTROL KIT 1. Open the steel curtains (remove glass doors if applicable). 2. Remove the log grate retaining screws and remove the log grate. 3.