BF45DXP, BF39STP, BF39DXP, BF33STP, BF33DXP Built in Firebox Owner's Manual
Table Of Contents
8 www.dimplex.com
Maintenance
WARNING: Disconnect power
and heater has cooled before
attempting any maintenance or
cleaning to reduce the risk of
re, electric shock or damage
to persons.
!
NOTE: The replace should
not be operated with an accumu-
lation of dust or dirt on or in the
unit, as this can cause a build up
of heat and eventual damage. For
this reason the heater must be
inspected regularly, depending
upon conditions and at least at
yearly intervals.
Light Bulb Replacement
Light bulbs need to be replaced
when you notice a dark section of
the ame or when the clarity and
detail of the log exterior disap-
pears. There are four bulbs under
the log set which generate the
ames and embers.
Helpful Hints: It is a good idea
to replace all light bulbs at one
time if they are close to the end
of their rated life. Group replace-
ment will reduce the number of
times you need to open the unit to
replace light bulbs. Long life bulbs
are recommended to reduce the
frequency of bulb changes.
Light Bulb Requirements:
Quantity of 4 clear chandelier or
candelabra bulbs with an E-12
(small) socket base, 60 Watt rat-
ing. Example: GE 60BC or Philips
60CTC. DO NOT EXCEED 60
WATTS PER BULB.
CAUTION: When handling log
only apply force to the ember bed
section not directly to the logs.
To access the light bulb area
CAUTION: Allow at least 5
minutes for light bulbs to cool off
before touching bulbs to avoid ac-
cidental burning of skin.
1. Open steel curtain (remove
glass doors if applicable).
2. Remove two screws on log
bracket and set aside
(Figure 2)
3. Pull front edge of plastic
ember bed or plastic grate up
and forward until rear tab re-
leases from the ledge located
at the bottom of the partially
reective glass (Figure 3).
Screws
Figure 2