HEATER (CONTINUED)
Problem Cause Solution
Service Manual
Reference
Heater fan runs
continuously
Loose wiring Trace wiring in unit Page 7
Defective heater on/off switch Replace heater on/off switch Page 14
Defective heater assembly Replace heater assembly Page 17
NOISE
Problem Cause Solution
Service Manual
Reference
Excessive noise
with the heater on
Dirty blower assembly Clean blower assembly
Defective blower assembly Replace heater assembly Page 17
Grinding or
excessive noise
with the heater off
Moving flame rod hitting or
rubbing against internal
components
Flame rod replacement Page 13
Defective flame motor Replace flame motor Page 13