Service manual

4 www.dimplex.com
Voltage Selector Switch
The BFSL33 has 2 voltage options at the time of installa-
tion, 110/120v and 220/240v. The voltage selector switch is
to be set at the time of installation according to the voltage
coming from the power supply.
The switch is located on the top right hand side of the
replace next to the overheat indicator light (Figure 1F).
The number 115 (for 110/120v) or 230 (for 220/240v) will be
visible on the switch. The voltage should be veried and
noted by the installer and homeowner for possible trouble-
shooting purposes in the future.
WARNING: Do not change the setting on the voltage
selector switch without verifying:
1. The incoming voltage from your power supply
2. The hardwire connections match your incoming
voltage according to the Dimplex BFSL33 Installa-
tion Instructions.
If they do not match it could lead to internal damage or non-
functioning components within the electric replace.
!
NOTE: If there is a need to change the voltage selector
switch position, ensure that the power to the unit
has been turned off and carefully insert a at head
screwdriver through the right side of the exhaust panel
into the notch on the switch. (Figure 1F) Then move
the switch either left or right to change it to the correct
position.
CAUTION: When changing the voltage selector switch,
ensure that the power supply is turned off.
Wall Mounted Controls
The replace can be installed with wall mounted controls.
These controls include wall switches, thermostats or wall
mounted remote controls. (See installation guide for de-
tailed installation instructions.)
1. Wall Mounted Switches
This model may be installed so that a wall mounted switch
energizes the rebox and dependent on the wiring can
control the operation/function of the ame and heat (On/
Off Switch must be in the ON position). For all wiring and
control options see the Installation Guide.
2. Wall Mounted Thermostat
This unit may be installed so that a wall mounted ther-
mostat can adjust the heat temperature to your individual
requirements. Please refer to thermostat manufacturers
operation Instructions.
3. Wall Mounted Remote Controls (WRCPF-KIT)
Dimplex manufactures a optional wall mounted remote
control which allows the user to fully control the replace
from a central location with the added functionality of a built
in thermostat.
MAINTENANCE
WARNING: Disconnect all power coming to replace
at main service panel before attempting maintenance
or cleaning to reduce risk of re, shock or damage to
persons.
Partially Reective Glass Cleaning
The partially reective glass is cleaned in the factory dur-
ing the assembly operation. During shipment, installation,
handling, etc., the partially reective glass surface may col-
lect dust particles. These can be removed by bufng lightly
with a clean dry cloth.
To remove ngerprints or other marks, the partially reec-
tive glass can be cleaned with a damp cloth using high
quality household glass cleaner. The partially reective
glass should be completely dried with a lint free cloth. To
prevent scratching, do not use abrasive cleaners or spray
liquids on any surface.