Owner’s Manual Model BLF3451 IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this fireplace. For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage. To view the full line of Dimplex products, please visit www.dimplex.
Table of Contents Welcome & Congratulations. . . . . . . . . . . . . . . . . . . . 3 IMPORTANT INSTRUCTIONS. . . . . . . . . . . . . . . . . . 4 Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . 6 Fireplace Installation . . . . . . . . . . . . . . . . . . . . . . . . . 7 Site Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Grounding Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Wiring. . . . . . . . . . . . . . . .
Welcome & Congratulations Thank you and congratulations for purchasing an electric fireplace from Dimplex. Please use our convenient online registration page to record your model and serial numbers for future reference at www.dimplex.com/register Serial Number Label Rating Label with Model Number Please carefully read and save these instructions. CAUTION: Read all instructions and warnings carefully before starting installation.
IMPORTANT INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following: ① Read all instructions before using this electric fireplace. ② This fireplace is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. The trim around the heater outlet becomes hot during heater operation. DANGER: High temperatures may be generated under certain abnormal conditions.
IMPORTANT INSTRUCTIONS line, paint, or flammable liquids are used or stored. ⑯ Use this fireplace only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons. ⑰ Do not change the plug in any way. Always plug heaters directly into a wall outlet/receptacle. Never use with an extension cord or relocatable power tap (outlet/power strip). ⑱ Do not burn wood or other materials in the electric fireplace.
Quick Reference Guide 1. The electrical information regarding your electric fireplace can be found on the rating label located on the front of the unit, behind the glass. Figure 1 6.8 in. (172 mm) 3.8 in. (95 mm) Please use our convenient online registration page to record your model and serial numbers for future reference at www.dimplex.com/register 16.0 in. 18.0 in. (406 mm) (457 mm) 2.
Fireplace Installation Site Selection Review and consider all of the following conditions before installation: • Dimensions of the unit: 34.1 in. (867 mm) x 19.4 in. (494 mm) • For surface installation, the unit requires a minimum of 2 wall studs in order to ensure secure installation. For other installation methods, suitable framing is required. sure that the power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire, electric shock or injury to persons.
Fireplace Installation Hardwire Installation is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. The fireplace is provided with a three prong plug installed for plug-in convenience. Hard wiring the fireplace is also an option for any installation. WARNING: Do not attempt to wire your own new outlets or circuits.
Fireplace Installation Figure 4 Figure 3 Electrical Cord Bracket Hardwire Bracket Screws cord bracket from the back of the fireplace by removing the three retaining screws. (Figure 3) 2. Remove the two wire access covers off of the unit at the front to access the wire connections. (Figure 4) 3. Pull the wires and connectors out of the back opening. 4. Unscrew the three wire connectors inside the electrical box and separate the wires. 5.
Fireplace Installation Figure 5 Figure 6 Wall Mounting Bracket Bottom Support Bracket For Bathroom Use If this unit is installed in a bathroom it must be protected by a GFI receptacle or circuit. If receptacle is used it must be readily accessible. To prevent electrical shock this unit is an electrical appliance that is NOT watertight and must be installed as to prevent water from entering unit. This must be installed away from showers, tubs, etc.
Fireplace Installation with the bubble level on the top, on the wall so that the bubble on the level is centered between the two black lines. 4. Mark the 3 mounting screw locations, on the wall, ensuring that the wall bracket stays level. (Figure 5) 5. In locations where the screws are being installed only into drywall, install the supplied wall anchors before installing the screw (predrill if required). 6. Secure the wall bracket to the wall using the supplied 1½ in. (3.
Fireplace Installation an outlet on a nearby wall stud within the wall). • Hard wire the fireplace (recommended). Follow the hard wiring instructions on page 8. WARNING: Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician. WARNING: Ensure that the circuit on which the fireplace is to be installed has the power cut off at the service panel until installation is complete. 3.
Fireplace Installation instructions on page 8. WARNING: Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician. WARNING: Ensure that the circuit on which the fireplace is to be installed has the power cut off at the service panel until installation is complete. 3. Lift fireplace and insert into opening. The fireplace's mounting trim should be flush against the wall (Figure 9). 4.
Fireplace Installation Figure 11 Front tray Figure 12 Tab Front glass assembly Hooks (4) Mounts (4) 14 www.dimplex.
Operation Figure 13 Figure 14 A C D E F Floating DisplayTM WARNING: This electric firebox must be properly installed before it is used. The unit can be controlled by either the manual controls which are located on the upper right of the fireplace or the remote (Figure 13 & 14). The fireplace is supplied with an IR multifunction remote control. TM A B C D E F G H for 5 seconds. B. Flame Effects Turns the flame effect On and Off. → Activated by pressing the ton on the remote. C.
Operation the Floating DisplayTM. Disable Heat a slight, harmless odor when first used. This odor is a normal condition caused by initial heating of internal heater parts and will not occur again. If desired, depending on the season, the heater on the unit can be disabled. The unit will operate in the same fashion, with remainder of the controls. ! NOTE: The heater may emit D & E. Thermostat Controls Adjusts the temperature set point to your individual requirements.
Operation G. Brightness Changes the brightness of the lights in the unit. → Adjusted by repeatedly pressing the corresponding button on the remote. • Indicated by the second digit on the Floating Display™ changing to show: "H" (high), and "L" (low). H. Sleep Timer The Sleep Timer can be set to automatically shut off the fireplace after a preset time (from 30 minutes to 8 hours).
Maintenance WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons. ! NOTE: The fireplace should not be operated with an accumulation of dust or dirt on or in the unit, as this can cause a build up of heat and eventual damage. For this reason the heater must be inspected regularly, depending upon conditions and at least at yearly intervals.
Warranty Products to which this limited warranty applies This limited warranty applies to your newly purchased Dimplex electric fireplace. This limited warranty applies only to purchases made in any province of Canada except for Yukon Territory, Nunavut, or Northwest Territories or in any of the 50 States of the USA (and the District of Columbia) except for Hawaii and Alaska. This limited warranty applies to the original purchaser of the product only and is not transferable.
Warranty repair or replace such defective product or part without charge. If Dimplex is unable to repair or replace such product or part, or if repair or replacement is not commercially practicable or cannot be timely made, Dimplex may, in lieu of repair or replacement, choose to refund the purchase price for such product or part. • Limited warranty service will be performed solely by dealers or service agents of Dimplex authorized to provide limited warranty services.
Replacement Parts Element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2200510300RP Partially Reflective Glass. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5902700100RP Blower. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5300170300RP Front Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6909140100RP Power Cord. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .