Model DAC12004RC Please read this manual carefully before use and keep it for future reference.
CONTENTS. Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FEATURES The air-conditioning unit is of the mono tube type, transportable (on wheels) with air/air operating system for domestic use and has 3 functions. • Ventilate/Fan. • Cool. • Heat. The ventilation mode "moves" the air allowing for its recycling much like a fan. The cooling mode, a refrigerating circuit (compressor), cools the room by transferring the heat from inside to outside though the air exhaust hose.While cooling, the airconditioning unit also dehumidifies the room air.
IMPORTANT SAFEGUARDS. • The air conditioning unit must always be stored and transported upright, otherwise you may cause irreparable damage to the compressor; in case of doubt we suggest you wait for at least 24 hours before you start the air-conditioning unit. • Avoid restarting the air conditioning unit unless 4 minutes have passed since its turned off or the compressor may get damaged. • Never use the mains plug as a switch to start and turn off the air conditioning unit.
• Please read the instructions carefully and save them in a safe place for future reference. 5 6 1 7 2 3 8 9 10 4 Know your Air Conditioner. 1. Control panel 7. Exhaust air outlet 2. Air outlet 8. Cord storage 3. Handle 9. Water stopper (rubber plug inside) 4. Castor 10. Water inlet draw 5. Air filter 6.
ACCESSORIES. 4 1. Adaptor - for insertion over hose and into back of the air conditioner 1 2. Exhaust hose 3 5 3. Foam strip - for filling the open window space and with hole for connection to exhaust hose 4. Foam strip - for filling the open window space 2 5. Round window connector 8 6. Cap for round window connector 6 7. Carbon Filter 8. Drain hose 9 9.
INSTALLATION Positioning of the unit This unit is a PORTABLE AIR CONDITIONER. It can be moved from room to room, so the cooling or heating can follow you anywhere.The installation is easy, beneath a window or wall. Please refer to either of the following ways – Foam strips 1. Using the foam strips • Connect the supplied foam strips with the exhaust pipe, allowing the hot or cold air to flow to the outside. • Should the foam strip(s) be too large, cut off the extra part to fit the window.
Mounting of the exhaust pipe 1. The supplied exhaust hose can be extended from 50cm to 150cm for mounting. It is recommended that you use the hose in the shortest possible length. 2. Take care to prevent any bow or bend in the middle of the exhaust hose, as this will trap hot exhaust air, which will radiate into the room and cause this unit to shut itself off due to overheating. WARNING! The length of the exhaust pipe is specially designed according to the specification of this product.
Adding Water. An added feature of these models. Humidity absorbed from the air condenses at the Evaporator, turns into water and is collected in the internal tank.When enough water is collected it is pumped up and over the condenser, assisting the cooling of the refrigerated gas, increasing the COOLING CAPACITY. Some of this recycled water is evaporated at condenser and expelled from the machine as water vapour though the exhaust hose.
OPERATION. 1. Power indicator 7 2. Fan operating indicator 3. Cooling operating indicator 4. FULL WATER indicator 5. Heating Operation Indicator. 6. Thermostat. 7. Selection switch. Fan Only, 6 8. Low fan Cool, High fan Cool, 8 1 2 3 4 5 9. Low Fan Heat, High Fan Heat. 10. Timer (1-8 hours) as well as ON/OFF switch. Turning ON/OFF • Set TIMER to ON for continuous operation (the unit will operate as long as it is not turned off). Power indicator comes on.
Regulating air flow direction Push the lever up or down to direct the air flow direction. NOTICE! To prolong the compressor’s life, the compressor will only work 3 minutes after you switch the unit on or re-switch on. The cooling system will switch off if the ambient temperature is lower than the set one. The ventilation however, keeps working on the set level. If the ambient temperature rises above the selected level, the cooling will return to work.
DRAINAGE. During the process of cooling, water will be generated from the air and collected in the water tank inside the unit.When the tank is full, the compressor will stop and the Full Water indicator on the control panel will come on to remind you to empty the water tank. During this time the fan will continue to operate circulating the air.The water tank should be emptied as follows: 1. Turn off the unit. 2. Position the supplied plastic water tray, flat on the floor, under the drain hole. 3.
MAINTENANCE. Always unplug the unit from the mains before beginning the cleaning. Cleaning the housing • Use a soft, damp cloth to wipe the body clean. • Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions.These all could possibly damage the cabinet. Cleaning the filter • Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water (no hotter than 40°C).
TROUBLE SHOOTING GUIDE. If the product is treated in the right manner, you should encounter no problems. In case of difficulties, please check the following points before consulting the maintenance service. Product does not work • Check whether the product is plugged in. No cool air • Has three minutes passed after switching on the unit, check whether the water tray is full. • The room temperature should be in the operation range of 18°C-32°C Cooling Mode • Is the set temp higher than the room temp.
/0%2!4)/. 0OWER INDICATON &AN OPERATING INDICATOR 63((' #OOLING OPERATING INDICATOR @&5,, WATER INDICATOR 7,0(5 7+(50267$7 (EATING /PERATING INDICATOR 4HERMOSTAT 3PEED SWITCH WITH OPTIONS FOR &!. ,/7 #//, ()'( #//, ,/7 (%!4 ()'( (%!4 4IMER HOURS AS WELL AS /. /&& SWITCH 4URNING /. /&& s 3ET 4)-%2 TO /.