Technical data
Table Of Contents
- Front Cover
- Table of Contents
- Reference Materials
- Product Overview
- Key Features/Benefits
- Easy to Use Communication and Human Interface Options
- Catalog Number Explanation
- Standard Drive Product Selection
- Factory Installed Options
- User Installed Options
- Product Dimensions
- Installation Considerations
- Cable Recommendations
- Power Ratings and Branch Circuit Protection
- Maximum Motor Cable Lengths
- PowerFlex 700L with 700VC Control, 400V Shielded/Unshielded Cable - Meters (Feet)
- PowerFlex 700L with 700VC Control, 480V Shielded/Unshielded Cable - Meters (Feet)
- PowerFlex 700L with 700VC Control, 600V Shielded/Unshielded Cable - Meters (Feet)
- PowerFlex 700L with 700VC Control, 690V Shielded/Unshielded Cable - Meters (Feet)
- PowerFlex 700L with 700S Control, 400V Shielded/Unshielded Cable - Meters (Feet)
- PowerFlex 700L with 700S Control, 480V Shielded/Unshielded Cable - Meters (Feet)
- PowerFlex 700L with 700S Control, 600V Shielded/Unshielded Cable - Meters (Feet)
- PowerFlex 700L with 700S Control, 690V Shielded/Unshielded Cable - Meters (Feet)
- DPI Connections
- Control Connections
- Control Highlights
- Standard Drive Specifications
- Derating Guidelines
- Watts Loss (@ Rated Load, Speed, and PWM Carrier Frequency)
- Cooling Loop Options
- Back Cover/Pub No./Date

PowerFlex 700L Technical Data
28 Publication 20L-TD001A
Frame 3B
Drive Connection Points
The PowerFlex 700L provides a number of cable connection points as shown in the drawings below. If an additional
external HIM is required for the application, the HIM can be connected to the DPI port on the bottom of the Power
Module. Only one additional external HIM device may be connected. The use of two external HIM devices is not
supported. If multiple external HIM devices are required, then install a user-supplied splitter cable or splitter box.
External Door-Mounted HIM Connection (optional)
For complete drives, the door-mounted HIM is standard equipment. It is located in the door mount bezel on the door of the
Power Module Bay.
Item Connector Description
➊
DPI Port 1 HIM connection when installed in Power Module.
➋
DPI Port 2 Cable connection for handheld and remote options.
➌
DPI Port 3 or 2 Splitter cable connected to DPI Port 2 provides an additional port.
➍
DPI Port 5 Cable connection for communications adapter.
➎
DPI Port 6 Internal DPI connection to Active Converter PCB.
Active
Converter
PCB
No Connections
Permitted
Blank HIM
No Connection
Permitted
No Communications
Adapter Permitted
Inverter-to-Converter
DPI Cable
Internal
DPI Cable
Internal
DPI Cable
➎
➋
Active Converter
Power Module
Inverter
Power Module
Bottom View of Power Modules
External
HIM Option
Inverter-to-Converter
DPI Cable
External
DPI Cable
Power Module
HIM Option
➊
➍
Communications
Adapter Option
➌
➋