Window/Wall Box Air Conditioner Cooling Only: DCB05C, DCB07C & DCB09C Reverse Cycle: DCB07, DCB09 & DCB14 INSTRUCTION MANUAL PLEASE READ THE INSTRUCTION MANUAL CAREFULLY BEFORE USING THE UNIT. www.dimplex.com.
Table of Contents Page Introduction 2 Operating Instructions 4 Electrical Specifications 5 Installation Instructions 6 Care and Maintenance 9 Trouble Shooting Guide 10 -1-
Introduction Front Cover Air inlet grille (Indoor) Cabinet Air outlet grille (Indoor) Air inlet grille (Outdoor) Vent Lever Control Panel Air filter Fig.
11 Compressor running
Operating Instructions Remote controller The remote controller transmits signals to the system. No.
CAUTION If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. DCB05C/DCB07C/DCB09C RECEPTACLE AND FUSE TYPES DCB05C DCB07C DCB09C RATED VOLTS 250V 250V 250V AMPS 7.1A 7.1A 7.1A RECEPTACLE AND FUSE TYPES DCB07/ DCB07 DCB09 RATED VOLTS 250V 250V 250V AMPS 7.1A 7.1A 8.
Installation instructions REMOVE ALL THE SHIPPING PARTS BEFORE INSTALLATION LOCATION Less than 210 Select a location that can support the weight of the air conditioner and one that will not cause increased operation noise and vibration. Direct sunlight is unfavorable for efficient cooling. Select a place where there is no obstacles near the air inlet and outlet. Less than 210 45 More than 55 Scrape lf the wall thickness is more than 210 scrape the wall as shown above.
Installation instructions CAUTION Do not install air conditioner in the place where flammable gas leaks are a possibility. The minimum clearance from the appliance to combustible surfaces is 100mm; (Only for electric heating) The range of external static pressures at which the appliance was tested is 0-5Pa OPERATION Check the capacity of wiring and power outlet. The power outlet should be used exclusively for the air conditioner. Do not use it with other appliances.
Installation instructions 1) Remove the front panel. (Fig.5) Remove the air filter. (Fig.6) Remove screw at the botton of the front panel. (Fig.7) Open the panel cover. 2) Remove the screws fix the chassis-fixing board and cabinet. some Models have two more screws on the back of the cabinet. (Fig.8) 3) Grasp the handle on the front of the chassis and carefully slide the air conditioner unit out of the cabinet. (Fig.
Care and Maintenance AIR FILTER The air filter should be washed at least once a month. lf the air filter remains full of dust, the air flow will decrease and the cooling capacity will be reduced. The filter is behind the cover and to be pulled out from right hand side. Wash the air filter with water and detergent. Rinse with clean water and dry completely before reinstalling. Fig.16 Fig.15 CAUTION Do not use hot water above 40 C f or washing t he air f ilter.
Troubleshooting Guide Never use hot water above 50 ,benzine,gasoline,acid,thinner or brush to wipe off dirt because they will damage the plastic surface and the coating. LONG OFF PERIOD MAINTENANCE Operate the fan alone ("LOW FAN"or"HIGH FAN") for half a day to dry out the inside of the unit. Turn off power and remove plug from wall socket.
CONTACT DETAILS Glen Dimplex Australia Pty Ltd 1340 Ferntree Gully Road Scoresby VIC 3179 Australia Ph: 1300 556 816 Web: www.dimplex.com.au Glen Dimplex New Zealand Ltd 38 Harris Road East Tamaki, Auckland New Zealand Ph: 09 274 8265 Web: www.dimplex.co.