Owner`s manual
!
NOTE: Ensurethelogsetisinstalledtightlyunderthebackledge
topreventlightleakage.
12
Lower
Bulbs
Upper
Bulbs
Trim
Front
Glass
Logset
Figure 8
Back
Ledge
Log
Emberbed
Rear
Tab
Front
Edge
Side Section
Figure 9
Upper Light Bulb Requirements
Quantityoftwo(2)clearchandelierorcandelabrabulbswithanE-12
(small)socketbase,15Wattrating.
Do not exceed 15 Watts per bulb
To access the upper light bulb area:
1. Slidereplaceoutofmantel.
2. Layunitonit’sbackforsaferemovaloffrontglass.
3. Removefour(4)Phillipsscrewsfromrightsideoftrim.
4. Removetrim.
5. Slideglasstotherightsideofthereplacetoremove.
6. Upperbulbslocatedintheupperleftandupperrightcornersof
replace.
7. Removeupperlightblockbyremovingthefour(4)mounting
screws.
8. Unscrewbulbscounterclockwise.
9. Insertnewbulbs.
10.Re-installupperlightbracket.
11.Layunitonit’sbackslidefrontglassbackintopositionandattach
trim.