Owner`s manual
6
Fireplace Installation
Installthereplaceassemblyintothemantel(refertomantelassembly
instructions).
!
NOTE 1: A15Amp,120Voltcircuitisrequired.Adedicatedcircuit
ispreferredbutnotessentialinallcases.Adedicatedcircuitwillbe
requiredifafterinstallationthecircuitbreakertripsorfuseblowson
aregularbasiswhentheheaterisoperating.Additionalappliances
on the same circuit may exceed the current rating of the circuit
breaker.
!
IMPORTANT: Ifnot
using a Dimplex mantel,
thereplacemustbe
installed in an enclosure
with the following
MINIMUM dimensions
(Figure5).
New Wall
Construction
1. Selectasuitable
location that is not
susceptibletomoisture
and is away from
drapes,furnitureandhightrafc.
2. Placethereplaceinthedesiredlocationtoseehowitwilllookin
theroom.
3. Markthedesiredlocationontheoor.
4. Usestudstoframeanopeningof26¾inch(679mm)wideX
23⅛inch(587mm)highX9inch(229mm)deep.
Option #1: Thepowercordcanberunfrombehindthetrimand
alongthewalltoanoutletnearthereplace.
Option #2: Anewoutletcanbeinstalledinsidetheframing
construction.
26¾”
(679mm)
23⅛”
(587mm)
9”
(229mm)
Figure 5