PARTS AND SERVICE MANUAL FOR THE ELECTRIC PATIO STOVE Model EOS2006
TABLE OF CONTENTS OPERATION PAGE 2 PARTS DRAWING PAGE 4 PARTS LIST PAGE 5 WIRING DIAGRAM PAGE 6 LIGHT BULB REPLACEMENT PAGE 7 FLAME ROD AND MOTOR REPLACEMENT PAGE 8 CIRCUIT BOARD REPLACEMENT PAGE 9 SWITCH REPLACEMENT PAGE 10 POWER CORD REPLACEMENT PAGE 11 1
EOS2006 OPERATION To access the controls go to the back of the Stove. A. MAIN ON/OFF SWITCH The on/off switch supplies power to all unit functions (flame/towel warmer) B. TOWEL WARMER ON/OFF SWITCH The towel warmer on/off switch supplies power to the towel warmer. The main on/off switch must be on to activate towel warmer switch. NOTE: When the Towel Warmer is switched ON, the warmer will operate. The warmer will not operate if the cooler insert is still in place within the unit.
TOWEL WARMER This unit has a convenient towel warmer built in. To operate the towel warmer remove cooler insert, activate towel warmer switch (fig.2), and place dry towels in towel warmer compartment.
11 2 8 7 9 10 6 3 5 4 4 1
EOS2006 REPLACEMENT PARTS OUTDOOR ELECTRIC STOVE CATALOGUE NO. PART NO. EOS2006 6903510159 REPLACEMENT PART 1. MOTOR, ASSEMBLY 2. CIRCUIT BOARD 3. MIRROR 4. FLAME ROD 5. BUSHING 6. LOGSET 7. POWER CORD 8. SWITCH, SPLASHPROOF 9. TERMINAL BLOCK 10. CAPACITOR 11.
WIRING DIAGRAM 6
EOS2006 LIGHT BULB REPLACEMENT Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental burning of skin. Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log exterior disappears. There are three bulbs under the log set which generate the flames and embers. HELPFUL HINTS It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life.
EOS2006 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. FLAME ROD AND MOTOR REPLACEMENT 1. Open door by pulling the handles. 2. Remove the screw from the logset located in the center of the emberbed and remove the logset from the unit. 1.
EOS2006 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. CIRCUIT BOARD REPLACEMENT 1. Open door by pulling the handles. 2. Remove the screw from the logset located in the center of the emberbed and remove the logset from the unit 3.
EOS2006 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. SWITCH REPLACEMENT 10 WARMER MAIN 1. Open door by pulling the handles. 2. Remove the screw from the logset located in the center of the emberbed and remove the logset from the unit 3.
EOS2006 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. POWER CORD REPLACEMENT 11 WARMER MAIN 1. Open door by pulling the handles. 2. Remove the screw from the logset located in the center of the emberbed and remove the logset from the unit 3.