SPLIT SYSTEM AIR CONDITIONER OWNER’S MANUAL & INSTALLATION MANUAL MODELS: GD09I - GD12I - GD18I Thank you for Choosing a Dimplex Air Conditioner, Please read this OWNERS MANUAL carefully prior to use.
CONTENTS Operation and maintenance Instructions prior to operation .................................... 2 How to use your air conditioner .................................. 3 Names and functions of each part ................................ 5 Operation of remote control .......................... 6 Emergency operation ................................... 11 Clean and care ........................................ 12 ....................................
Operation and maintenence This Dimplex Air conditioner must be installed by a qualified installer. Unplug the air conditioner when not used for a long period. Select the most appropriate temperature. We recommend setting the temperature o at 18 - 20 C The appliance also needs to bi-wired by a qualified electrician. Failure to follow any terms depicted in this manual will void the warranty. Do not leave windows and doors open for extended periods whilst running the air conditioner.
Instructions prior to operation The airflow direction is adjustable. The vertical direction of the airflow can be adjusted with the upward/downward louvers. The horizontal direction of airflow can be adjusted with the left / right louvers. If the power cord is damaged, it must be replaced by the manufacturer or a service agent or a similarly qualified person in order to avoid a hazard.
How to use your Dimplex Air Conditioner Working mechanism and special functions for cooling mode Principle: Air conditioners absorb the heat in a room, then transmit that heat outdoors, where it is then discharged. This decreases the ambient indoor temperature. The cooling capacity of the air conditioner may increase or decrease depending on the outdoor ambient temperature.
How to use your Dimplex Air Conditioner Anti-cool air function: The unit is designed not to blow cold air on HEAT mode when the indoor heat exchanger is in one of the following three situations: 1. When heating mode begins 2. After the auto-defrost function has just finiished. 3. Heating in very low temperatures. Gentle Breeze The unit may automatically rotate to a certain position and blow a gentle breeze in the following situations: 1.
Names and functions of each part Indoor unit Air inlet ⑴ ⑶ ⑷ ⑸ ⑹ Air outlet Icons on display: ⑺ ⑵ :Cool :Dry Remote Control :Fan ⑴ Power cable :Hea t ⑵ Remote control :Run ⑶ Front panel :Se t temp.
Operation of remote control Descriptions and functions of remote control Make sure there is nothing obstructing the receiver or the remote control. Do not drop or throw the remote control. Keep liquids away from the remote control. Do not place the remote control in direct sunlight, or keep near very high temperatures. SLEEP Signal transmitter SLEEP button Press this button to go into SLEEP mode. Press it again to cancel. When the unit is turned on, the SLEEP mode is automatically off.
Operation of remote control Description and functions of remote control Please note: The remote control is the same for all units. Should your unit not support all the functions displayed on the remote control, pressing those buttons will not affect your unit. Some functions are model specific. + - + and - buttons Press these buttons to change the temperature.Press and hold to change more rapidly. In AUTO mode, the temperature can not be altered.
Operation of remote control Description and functions of remote control Please note: The remote control is the same for all units. Should your unit not support all the functions displayed on the remote control, pressing those buttons will not affect your unit. TIMER ON ● Press this button to set and activate the TIMER. To set the TIMER, press this button once. The [clock icon] will disappear, and the time displayed will change from the CLOCK to the TIMER. The word ON will blink for five seconds.
Operation of remote control Guide for - General operation 1. Press this button to turn the unit ON. Press it again to turn the unit OFF. When the unit is turned off, the guide louver will close automatically. 2. Press the MODE button to select the desired running mode. 3. Press the + and - buttons to set the temperature. If this unit is in AUTO mode, this step is unnecessary. 4. Press the FAN button to set the fan speed. Available selections are AUTO, LOW, MEDIUM, and HIGH. 5.
Operation of remote control ‘Lock’ Feature Press +and - buttons simultaneously to lock or unlock the remote. If the remote control is locked, the will be displayed. If a button is pushed while the keypad is locked, the will flash. When the keyboard is unlocked, the [lock icon] will disappear Swing Glider Operation 1. To change the angle of the guide louver, press and hold the SWING button. After about two seconds, the louver will start to swing.
Emergency operation Turning the display light on/off The LIGHT button allows you to turn the light on and off. You can use this feature to turn on/off the ambient light of the unit if you intend to sleep whilst the unit is operating. To turn the display light on: Press the LIGHT button. The will appear on the remote control screen, and the light will turn on. To turn the display light off: Press the LIGHT button again. The the light will turn off.
Clean and care Caution Before cleaning, turn the power off and unplug the unit to prevent electric shock. To clean, use a damp cloth to wipe the unit down. Never put water on or in the unit when cleaning, or electric shock may occur. Never use flammable liquids to clean the air conditioner. To clean the front panel To clean the front panel, use a cool or lukewarm damp cloth and wipe the panel down. Never immerse the front panel in water, as this will damage the microcomputer and its circuits.
Clean and care Check before use ① Make sure nothing is obstructing the intake or outlet vents. ② Make sure the ground wire is properly connected. ③ Check the batteries. ④ Make sure the outdoor stand is not damaged. If it is, please contact the retailer for further assistance. Maintenance and Upkeep ① Turn main power off. ② Clean the filter and wipe down the outside surfaces. ③ Clear dust and obstructions from the outdoor unit.
Troubleshooting CAUTION Do not attempt to repair the unit by yourself. If the unit is not functioning properly, please check the following troubleshooting guide before contacting Dimplex customer services. Malfunction Solution The unit does not restart. Waiting Once the air conditioner has been turned off, it will not restart within three minutes. This is to prevent system overload. There is a bad smell coming from the unit. Clean the air filter.
Troubleshooting Malfunction The unit is not running. . Solution ● Is the power turned off? ● Has the cable come out of the outlet? ● Has the circuit breaker tripped? ● Is the voltage of the outlet too high or too low? (Please get a professional to test this.) ● Is the TIMER on? The unit is not cooling or heating efficiently.
Troubleshooting Malfunction Indoor unit is not blowing out any air. Solution ● If the unit is running in HEAT mode and the temperature of the heat exchanger is very low, it will stop before cold air comes out. ● When the unit is running in HEAT mode and the outdoor temperature is low or the humidity is very high, frost may form on the outdoor heat exchanger. If this happens, the unit will automatically defrost. During the defrosting, air will stop blowing, and water or vapour may come out of the unit.
Installation Instructions Important Notices 1.The unit must be installed by a qualified technician. Local laws and the instructions in this manual must be observed. 2.If the unit is not installed by an accredited installer, the unit may not be installed properly and malfunctions may occur. The Dimplex 5 year warranty will also be void.
Installation Instructions Safety Requirements For Electric Appliances 1. The circuit and power supply must be compatible with the unit and cable. 2. Do not yank or tug on the power cable. 3. This unit must be properly grounded, and should therefore be installed by a qualified technician. 4. The unit should be installed at least 1.5 metres away from any flammable surface. 5. The unit must be installed in compliance with national and local wiring regulations. 6.
Installation dimension diagram Installation dimensions diagram Distance to the ceiling or more Distance to the wall or more or more Distance to the wall 200 250 or more or more Air outlet side Distance to the floor Distance to any obstruction or more This diagram shows the necessary dimensions for the location of the unit.
Installing the indoor unit Installing the rear panel 1. Always mount the rear panel horizontally. As the water tray in the indoor unit has been designed to drain two ways, it is important to install the the water tray on a downward-sloping angle. 2. Use screws to attach the rear panel to the wall. 3. Make sure the panel can support a weight up to 60 kgs. The weight should be evenly distributed amongst the screws.
Installing the indoor unit NOTE: Make sure the wires are all properly connected. Improper connections may result in malfunctions of the unit. Tighten the terminal screw to prevent the wires from disconnecting. Once the screw is tightened, tug gently on the wire to make sure it is properly connected. If the grounding wire is not properly connected, it may cause electric shock. The cover plate and connection wires must be properly attached.
Installing the outdoor unit Electric wiring 1. Pull the handle on the right hand side of the outdoor unit. Handle 2. Undo the clasp. Attach the power cable and signal control wire to the terminal. The wiring should match that of the indoor unit. 3. Attach the power cable to the wire clamp, then N(1) 2 BU BK 3 BN YEGN connect the corresponding connector. 4. Make sure all wires are properly connected. 5. Reattach the handle. PLEASE NOTE: Incorrect wiring may cause the unit to malfunction.
Post-installation checklist and operation test Check after installation Things to check If improperly installed... Is the unit securely attached to the wall? The unit may shake, make loud noises, or fall down. Have you done the refrigerant leakage test? The unit may not heat or cool efficiently. Is the unit properly insulated? Condensation may form. Is the water draining properly? The unit may leak.
Installation and Maintenance of Silver Ion Filter Installation Instructions 1. Pull up gently on the front cover. The cover will hinge upward. Pull the air filter down and out of the unit (see Figure a). Fig. a Fig. b 2. Mount the Silver Ion filter onto the air filter, (as shown in Figure b). If the air filter cannot be installed, mount the Silver Ion filter on to the front case. (as shown in Figure .c) Air filter Silver Ion filter Air filter Fig. c 3. Slide the air filter back into the unit.
Contact Details: Glen Dimplex Australia Pty Ltd 2/205 Abbotts Road Dandenong South 3175 Victoria, Australia Phone: 1300 556 816 Fax: 1800 058 900 Email: sales@glendimplex.com.au web: www.dimplex.com.au Glen Dimplex New Zealand Ltd P.O. Box 58473 Botany Manukau 2163 New Zealand Phone: 09 274 8265 Fax: 09 274 8472 Email: sales@glendimplex.co.nz web: www.dimplex.co.