Technical data

www.dimplex.de/en
15
2012
Air-to-water heat pump in split design
Max. flow temperature 55 °C
Casing colour White
Air-to-water heat pump in split design
LIA 7-9IM
LIA 12-16IM
Heat pump for heating with hydraulic unit (indoor) – and an outdoor unit, which are connected via a refrigerant pipe (special accessory).
The outdoor unit with an output-regulated compressor (inverter) adapts the heat output to the heat consumption of the building and
can be installed close to walls. The electrical connection between the indoor and outdoor units is via a 4-wire cable not included in the
scope of supply. The hydraulic unit contains the following components:
Heat exchanger for connecting an unmixed heating circuit
Circulating pump for heating and domestic hot water preparation
Integrated pipe heater 3 kW (LIA 7-9IM)
Integrated pipe heater 6 kW (LIA 12-16IM)
Safety valve and expansion vessel 10 l
Display with segment display
Simplified regulation for heating and domestic hot water preparation with external temperature-led heating regulation for mono energy
operation and definable time windows for domestic hot water preparation. Bivalent connection as return temperature lowering without
domestic hot water preparation. External, flow and return sensors integrated in the heat pump.
Lower operating limit heat source (heating operation) -20 °C ; Upper operating limit heat source (heating operation) 35 °C ;
Refrigerant R410A ; Connection heating ¾ ˝ ; Connection voltage 1/N/PE ~230 V, 50 Hz
Order reference Art.-no. Heat output
with 1 compres-
sor / COP
A7/W35
Outdoor
component
weight
kg
Indoor
component
weight
kg
Indoor component
width x Height x
Depth
mm
Outdoor component
width x Height x
Depth
mm
LIA 7IM 365180
7.0 / 4.4
66 34 504 x 644 x 295 900 x 795 x 320
LIA 9IM 365190
9.0 / 4.1
LIA 12IM 365200
12.0 / 4.6
106 50 502 x 892 x 353 900 x 1340 x 320
LIA 14IM 365210
14.0 / 4.5
LIA 16IM 365220
16.0 / 4.2
Heat output and coefficient of performance (COP) according to EN 14511 at A7/W35 (A7 = air intake temp. +7 °C, W35 = heating water outlet temp.
+35 °C)
It is absolutely essential that the commissioning of the split heat pump takes place via after-sales service (IN 30 WPS) owing to the cooling techno-
logy training required to connect the indoor and outdoor units. Dimplex split heat pumps feature a single-phase electrical connection (230 V).
They do not automatically meet the applicable technical connection conditions (TCC). Consent should therefore be obtained from the utility
company prior to connection. A utility block can be implemented via a contactor provided by the customer which disconnects all power to the
heat pump.
LIA 7IM 365180 4015627365186
LIA 9IM 365190 4015627365193
LIA 12IM 365200 4015627365209
LIA 14IM 365210 4015627365216
LIA 16IM 365220 4015627365223
Refrigerant pipes for split heat pump
SKML ...
Empty refrigerant pipes according to EN-12735-1 with protective caps, including UV-resistant polyethylene-based insulation; wall thick-
ness Cu 0.8 – 1.0 mm; Insulation thickness 9 mm.
Order reference Art.-no. For device type Length
m
Cross section refrigerant pipe
˝
SKML 725 365760
LIA 7-9IM 25
/
SKML 1225 365770
LIA 12-16IM 25
³
/
SKML 725 365760 4015627365766
SKML 1225 365770 4015627365773
Electric band heater
For heating the condensate tray
KWH 60
Thermostatically regulated band heater for heating the metal condensate tray (on/off temperature: 5 °C/10 °C), power supply from
external unit of the split heat pump.
Order reference Art.-no. Length
m
Rated power
W
Connection voltage
KWH 60 365270
1.5 60 1/N ~230 V, 50 Hz
A condensate drain heater must be installed if the split heat pump is used beneath the frost line.
KWH 60 365270 4015627365278
Split air-to-water heat pump wall bracket
WKS 357
Order reference Art.-no. For device type Features
WKS 357 343230
LIA 7-9IM
Wall bracket for mounting the outdoor com-
ponent e.g. on an external wall incl. damping
elements and fixing material. (Set of 2 brackets)
WKS 357 343230 4015627343238
Air-to-water heat pump for outdoor installation
Dirt trap
SMF ..
Dirt trap for installation into the heating circuit (return to the heat pump), suitable for all non-corrosive substances up to 150 °C.
To protect the heat pump against damage caused by impurities and thus extend its service life.
Order reference Art.-no. For device type Connection heating
˝
Mesh size
mm
Weight
kg
SMF 25-04 363840
LIA 7-9IM 1
0.4
1 .0
SMF 32-04 364030
LIA 12-16IM 1.2
SMF 25-04 363840 4015627363847
SMF 32-04 364030 4015627364035