Technical data
www.dimplex.de/en
19
2012
Air-to-water heat pump for indoor installation
Max. flow temperature 65 °C
Casing colour White (similar to RAL 9003)
Medium temperature air-to-water heat pump
Compact design
LIKI 14TE
Heat pump for heating purposes for indoor installation with integrated WPM 2007 plus controller. The control panel is integrated into
a brown-red design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). The
integrated air circuit with 90° air deflection enables installation in a corner without air ducts or wall installation with air ducts on the air
outlet side. High coefficients of performance (COP) thanks to compliance with EN 14511 for larger volume flows on the heat consump-
tion side, optimised high-performance evaporator for heating operation and dual differential pressureless manifold for reducing pump
operating time. Sound-optimised through low-noise fan and insulated metal casing; integrated solid-borne sound insulation for direct
connection to the heating system with free-swinging compressor base plate.
Compact design with optional domestic hot water preparation and integrated components for direct connection of an unmixed heating
circuit (must not be used for bivalent systems):
• Circulating pump (observe the free compression)
• Expansion vessel (24 l)
120 l buffer tank (can be dismantled) with integrated switchable supplementary heating 3/6 kW, safety module. Soft starter, integrated
flow and return sensors; external sensor (standard NTC-2) included in the scope of supply. A heat circulating pump not included in the
scope of supply is required for the distribution system.
Lower operating limit heat source (heating operation) -20 °C ; Upper operating limit heat source (heating operation) 35 °C ;
Refrigerant R417A ; Control voltage ~230 V ; Connection heating 1¼ ˝ ; Connection voltage 3/N/PE ~400 V, 50 Hz
Order reference Art.-no. Heat output 1 compressor /
COP A2/W35
Air outlet Width x Height x Depth
mm
Weight
kg
LIKI 14TE 356010
9.9 / 3.4 Right 960 x 2100 x 780 365
Heat output and COP according to EN 14511 at A2/W35.
For the air circuit, varying duct dimensions must be used (air intake side 800, air outlet side 600). Transport heights when disassembled: Heat
pump with hydraulics approx. 1.65 m, buffer tank approx. 55 cm.
LIKI 14TE 356010 4015627356016
Air connection plate for air outlet side LIKI 14TE
For modification of the air circuit
ABL 14
Air connection plate for mounting on the LIKI 14TE air-to-water heat pump. By mounting the side covering panel onto the left side of the
heat pump, the air outlet side can be moved from the standard right-side air circuit to the opposing left side; side wall painted (white,
similar to RAL 9003) assembly material included.
Order reference Art.-no. For device type Weight
kg
ABL 14 358210
LIKI 14 - outlet 3.5
ABL 14 358210 4015627358218
Air-to-water heat pump with straight air circuit
Max. flow temperature 60 °C
Casing colour White (similar to RAL 9003)
Low temperature air-to-water heat pump
Universal design
LI 11TES
Heat pump for heating purposes for indoor installation with integrated WPM 2007 plus controller. The control panel is integrated into
a brown-red design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). The
integrated air circuit enables corner or wall installation with air ducts at the air intake and the air outlet side. Sound-optimised through
low-noise axial fan and vibration-isolated compressor. High coefficients of performance (COP) using an evaporator optimised for heating
operation and energy-efficient defrosting by reverse circulation. Universal design with optional domestic hot water preparation and
flexible expansion possibilities for:
• Bivalent or bivalent-renewable operating mode
• Distribution systems with unmixed and mixed heating circuits
• Built-in pipe heater (2/4/6 kW)
At an external temperature of -10 °C, the maximum flow temperature that can be achieved is 53 °C. Soft starter, integrated flow and
return sensors; external sensor (standard NTC-2) included in the scope of supply.
Lower operating limit heat source (heating operation) -20 °C ; Upper operating limit heat source (heating operation) 35 °C ;
Refrigerant R410A ; Connection heating 1¼ ˝
Order reference Art.-no. Heat output
1 compressor /
COP A2/W35
Connection
voltage
Air outlet Width x Height x Depth
mm
Weight
kg
LI 11TES 366050
8.3 / 3.6
3/N/PE ~400 V,
50 Hz
Right
750 x 1360 x 880 216
LI 16TES 366060
12.6 / 3.2 750 x 1570 x 880 245
Heat output and COP according to EN 14511 at A2/W35.
LI 16TES available from Octobre 2012 onwards.
LI 11TES 366050 4015627366053
LI 16TES 366060 4015627366060