Technical data
www.dimplex.de/en
30
2012
Brine-to-water heat pump in universal design
Max. flow temperature 58 °C
Casing colour White (similar to RAL 9003)
Low temperature brine-to-water heat pump
Universal design
SI 5ME
Heat pump for heating purposes for indoor installation with integrated WPM 2007 plus controller. The control panel is integrated into a
brown-red design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD). Vari-
able connection options for brine and heating connections on the back board of the casing. Sound-optimised through insulated metal
casing and double vibration-isolated compressor. Economiser for high coefficients of performance (COP). Universal design with optional
domestic hot water preparation and flexible expansion possibilities for:
• Bivalent or bivalent-renewable operating mode
• Distribution systems with unmixed and mixed heating circuits
Soft starter (from 9 kW), integrated flow and return sensor; external sensor (standard NTC-2), dirt filter for brine circuit included in the
scope of supply.
Brine package and brine circuit manifold must be ordered separately.
Lower operating limit heat source (heating operation) -5 °C ; Upper operating limit heat source (heating operation) 25 °C ;
Refrigerant R407C
Order reference Art.-no. Heat output 1 compressor /
COP at B0/W35
Connection voltage Width x Height x Depth
mm
Weight
kg
SI 5ME 353010
4.9 / 3.8
1/N/PE ~230 V, 50 Hz 650 x 805 x 462
109
SI 7ME 353020
6.3 / 4 .0 111
SI 9ME 353030
8.9 / 4 .0 118
SI 11ME 353040
11.0 / 4.1 122
SI 14ME 353050
15.6 / 4.1 130
Heat output and coefficient of performance (COP) according to EN 14511 at B0/W35.
SI 5ME 353010 4015627353015
SI 7ME 353020 4015627353022
SI 9ME 353030 4015627353039
SI 11ME 353040 4015627353046
SI 14ME 353050 4015627353053
Max. flow temperature 70 °C
Casing colour White (similar to RAL 9003)
High-temperature brine-to-water heat pump
Universal design with high coefficients of performance (COP)
SIH 6TE
Heat pump for heating purposes for indoor installation with integrated WPM 2007 plus controller. The control panel is integrated into
a brown-red design screen and can also be used as wired remote control using the wall mounting set (special accessories MS PGD).
Variable connection options for brine and heating connections on the back board of the casing. Sound-optimised through insulated
metal casing and double vibration-isolated compressor. High coefficients of performance (COP) with economiser and compliance with
the requirements of EN 14511 for larger volume flows on the heat consumption side. Universal design with optional domestic hot water
preparation and flexible expansion possibilities for:
• Bivalent or bivalent-renewable operating mode
• Distribution systems with unmixed and mixed heating circuits
Integrated soft starter and load contactor for brine circulating pump, integrated flow and return sensors; external sensor
(standard NTC-2) and dirt filter for brine circuit included in the scope of supply.
Brine package and brine circuit manifold must be ordered separately.
Lower operating limit heat source (heating operation) -5 °C ; Upper operating limit heat source (heating operation) 25 °C ;
Refrigerant R134a
Order reference Art.-no. Heat output 1 compressor /
COP at B0/W35
Connection voltage Width x Height x Depth
mm
Weight
kg
SIH 6ME 355170
6.0 / 4.1
1/N/PE ~230 V, 50 Hz
650 x 805 x 462
118
SIH 9ME 355180
8.9 / 4 .0 130
SIH 11ME 355190
10.7 / 4.5 133
SIH 6TE 355140
6.1 / 4.5
3/N/PE ~400 V, 50 Hz
118
SIH 9TE 355150
8.9 / 4.4 130
SIH 11TE 355160
10.9 / 4.5 133
Heat output and coefficient of performance (COP) according to EN 14511 at B0/W35.
The maximum flow temperatures (up to 70 °C) are available for domestic hot water preparation all year round, and allow domestic hot water
temperatures of up to 60 °C to be achieved without electrical reheating using a flange heater.
SIH 6ME 355170 4015627355170
SIH 9ME 355180 4015627355187
SIH 11ME 355190 4015627355194
SIH 6TE 355140 4015627355149
SIH 9TE 355150 4015627355156
SIH 11TE 355160 4015627355163
Brine-to-water heat pump connection kit
VSH BS
Hose kit for connecting a heat pump to the KPV 25 compact manifold or the VTB 25 manifold bar. The set contains two flexible Wellflex
pipes (length 1190 mm and 710 mm) with high and low temperature insulation for fast and easy installation and 1¼“ cap nut (can also
be used for connecting the brine circuit). Two double nipples 1¼“ external thread to 1“ external thread included in the scope of supply.
Order reference Art.-no. For device type
VSH BS 347790
SI(H) 6 - 18 heating circuit
SIH 6 - 11TE brine circuit
VSH BS 347790 4015627347793
Heat pump for heating purposes - ground as heat source