Technical data
www.dimplex.de/en
31
2012
Design built-under buffer tank
PSP 100E
Nominal capacity 100 l; in brine-to-water heat pump design to enable space-saving installation on top of the built-under buffer tank;
polyurethane insulation for minimal downtime losses (can be used for heating and cooling); 1½“ sleeves for immersion heaters
(up to CTHK 635); 1¼“ heating water connections; colour: white; brown red design screen.
Order reference Art.-no. Short text For device type Width x Height x Depth
mm
Weight
kg
PSP 100E 353360
Built-under buffer tank
SIK 7 - 14
SI 6 - 14TU
SIH 6 - 11TE
WI 10 - 14TU
650 x 550 x 653 54
PSP 100E 353360 4015627353367
Design built-under domestic hot water cylinder
WWSP 229E
Nominal capacity 227 l, in brine-to-water heat pump design to enable space-saving installation on the built-under domestic hot water
cylinder, bare-tube heat exchanger (internal), steel cylinder (special inside enamelling) with protection anode, polyurethane insulation
with minimum standby losses; integrated temperature sensor for connection to the heat pump manager, colour: white, brown red
design screen.
Permissible operating pressure 10 bar; Flange TK150/DN110 ;
Order reference Art.-no. For
device
type
Usable
capacity
l
Heat ex-
change
surface
m²
Con-
nection
heating
˝
Con-
nection
circula-
tion
˝
Con-
nection
DHW
˝
Width x Height x
Depth
mm
Weight
kg
WWSP 229E 353380
Up to
SI(K) 9
206 2.9 1¼ ¾ 1 650 x 1040 x 680 110
Recommended for service areas without shut-off times or with reduced domestic hot water consumption.
The achievable hot water temperatures are dependent on the maximum heat output of the heat pump, the heat exchange surface and the volume
flow in the load circuit (dimensioned for max. hot water temperatures of 45 °C according to the project planning documentation). For heat pumps
with two performance levels, domestic hot water preparation is achieved with a compressor.
WWSP 229E 353380 4015627353381
Brine package for brine-to-water heat pump
With one performance level
SZB: safety module
SZB: large-capacity breather
Brine circuit accessory package consisting of an installation-friendly, premounted safety module with connection for an expansion vessel
(18 litres/0.5 bar admission pressure), 1½“ main breather and brine pump for ground heat collectors according to the project planning
documentation incl. two 1½“ ball valves (without brine circuit manifold and pipework). The free compression must be checked if the
dimensions deviate or if borehole heat exchangers are used.
Order reference Art.-no. For device type Circulating pump Weight
kg
SZB 680 336680
SI(H) 6 - SI 14 Top-S 25/7,5 24
SZB 700 336700
SI 17TE Top-S 30/10 21
With borehole heat exchangers, the free compression values in the device information are to be adhered to (max. heat exchanger depth at DN 32:
80 m)!
SZB 680 336680 4015627336681
SZB 700 336700 4015627336704
Elasticated sound insulation strip
SYL 250
For solid-borne sound insulation of heat pumps for indoor installation and compensation of floor unevenness; strip-shaped support for
the base frame; 12 mm thick (deformation approx. 1 mm); max. load 140 kg/RM; 2.5 m long (can be cut to appropriate length),
colour: green.
Order reference Art.-no. Length
mm
Width x Height
mm
Weight
kg
SYL 250 352260
2500 30 x 12 0.3
SYL 250 352260 4015627352261
Heat pump for heating purposes - ground as heat source