Technical data

www.dimplex.de/en
45
2012
Design domestic hot water cylinder
WWSP 442E
Nominal capacity 400 l, in brine-to-water heat pump design, bare-tube heat exchanger (internal), three supporting feet, steel cylinder
(special inside enamelling) with protection anode, polyurethane insulation with minimal standby losses (approx. 2.7 kWh/24 h), integra-
ted temperature sensor for connection to the heat pump manager, colour white, brown red design screen.
Order reference Art.-no. For device
type
Usable
capacity
l
Heat ex-
change
surface
Con-
nection
heating
˝
Con-
nection
circula-
tion
˝
Con-
nection
DHW
˝
Width x Height x
Depth
mm
Weight
kg
WWSP 442E 353370
SIK 7 - 14
SI(H) 20 - 30
353 4.2 ¾ 1 650 x 1660 x 680 187
The achievable hot water temperatures are dependent on the maximum heat output of the heat pump, the heat exchange surface and the volume
flow in the load circuit (dimensioned for max. hot water temperatures of 45 °C according to the project planning documentation). For heat pumps
with two performance levels, domestic hot water preparation is achieved with a compressor.
WWSP 442E 353370 4015627353374
Design built-under domestic hot water cylinder
WWSP 229E
Nominal capacity 227 l, in brine-to-water heat pump design to enable space-saving installation on the built-under domestic hot water
cylinder, bare-tube heat exchanger (internal), steel cylinder (special inside enamelling) with protection anode, polyurethane insulation
with minimum standby losses; integrated temperature sensor for connection to the heat pump manager, colour: white, brown red
design screen.
Permissible operating pressure 10 bar; Flange TK150/DN110 ;
Order reference Art.-no. For
device
type
Usable
capacity
l
Heat ex-
change
surface
Con-
nection
heating
˝
Con-
nection
circula-
tion
˝
Con-
nection
DHW
˝
Width x Height x
Depth
mm
Weight
kg
WWSP 229E 353380
Up to
SI(K) 9
206 2.9 ¾ 1 650 x 1040 x 680 110
Recommended for service areas without shut-off times or with reduced domestic hot water consumption.
The achievable hot water temperatures are dependent on the maximum heat output of the heat pump, the heat exchange surface and the volume
flow in the load circuit (dimensioned for max. hot water temperatures of 45 °C according to the project planning documentation). For heat pumps
with two performance levels, domestic hot water preparation is achieved with a compressor.
WWSP 229E 353380 4015627353381
Flange heater for domestic hot water cylinders
FLH 60
For reheating and thermal disinfection; temperature controller, adjustable from 30–80 °C; safety temperature limiter, suitable for all hot
water cylinders (WWSP), unheated length 105 mm, diameter 185 mm.
Order reference Art.-no. Connection voltage Heat output
kW
Flange Immersion depth
mm
FLH 25M 349430
1/N/PE ~230 V, 50 Hz 2.5 TK150/8 360
FLHU 70 338070
3/N/PE ~400 V, 50 Hz 4 .0 TK150/8 360
FLH 60 338060
3/PE ~400 V, 50 Hz 6 .0 TK150/8 360
FLH 90 366130
3/PE ~400 V, 50 Hz 9 .0 TK150/8 580
FLH 90 available for delivery from June 2012 onwards.
FLH 25M 349430 4015627349438
FLHU 70 338070 4015627338074
FLH 60 338060 4015627338067
FLH 90 366130 4015627366138
Accessories for domestic hot water cylinders
SVK 852
KRRV 003
Order reference Art.-no. Short text Features Weight
kg
SVK 852 326660
Safety valve
combination
For the cold water connection of domestic water cylinders
to the supply network according to DIN 1988. 1“ external
thread connection; DN 20, 8 bar, yellow.
1.5
KRRV 003 322070
Thermostat for heating
and domestic hot water
Capillary tube controller setting range: 0–70 °C switching
capacity at 230 V, 50 Hz, 10 A switching temperature difference:
1.0–2.0 K, sheath tube length: 200 mm.
0.5
SVK 852 326660 4015627326668
KRRV 003 322070 4015627322073
Accessories for heat pumps for heating purposes