Technical data

www.dimplex.de/en
53
2012
Heat pump regulation and accessories
Heating controller - heat pump manager
WPM 2006 plus
WPM EconPlus
Controller for heat pump heating systems for installation in frost-free rooms, with backlit LCD, time-controlled lowering and raising of
the heating characteristic curve, timer functions for domestic hot water preparation according to need by heat pump, with optional tar-
geted reheating by flange heater. ‚Bivalent-renewable‘ operating mode for combining the heat pump with additional renewable energy
sources such as wood or solar heat; dynamic input menus with different levels for technicians and users. Two independent mixer outputs
for controlling an additional heat generator and a maximum of two mixed heating circuits. Automatic program for targeted heat drying
of screed floors. PC, modem and bus connection via plug-in modules (special accessories); external sensor (standard NTC-2) included in
the scope of supply.
Order reference Art.-no. Features Width x Height x Depth
mm
Weight
kg
WPM 2006 plus 352550
Delivered as a wall mounted controller in the scope of supply of
the air-to-water heat pump for outdoor installation.
370 x 330 x 90 4.1
WPM EconPlus 355950
Delivered as a wall mounted controller in the scope of supply of
the air-to-water heat pump for outdoor installation. Integrated
thermal energy meter with separate evaluation for heating and
domestic hot water preparation. Simplified electrical connection
with separate terminal blocks for 24 V and 230 V.
303 x 489 x 120 5 .0
WPM 2006 plus 352550 4015627352551
WPM EconPlus 355950 4015627355958
Heat pump manager for heating and cooling
Controller for heat pump heating systems for installation in frost-free rooms, with backlit LCD, time-controlled lowering and raising of
the heating characteristic curve, timer functions for domestic hot water preparation according to need by heat pump, with optional tar-
geted reheating by flange heater. ‚Bivalent-renewable‘ operating mode for combining the heat pump with additional renewable energy
sources such as wood or solar heat; dynamic input menus with different levels for technicians and users. Two independent mixer outputs
for controlling an additional heat generator and a maximum of two mixed heating circuits. Automatic program for targeted heat drying
of screed floors. PC, modem and bus connection via plug-in modules (special accessories); external sensor (standard NTC-2) included in
the scope of supply.
Order reference Art.-no. Features Width x Height x Depth
mm
Weight
kg
WPM EconR 358380
Delivered as a wall mounted controller in the scope of supply of
the air-to-water heat pump for outdoor installation. Integrated
thermal energy meter with separate evaluation for heating and
domestic hot water preparation. Simplified electrical connection
with separate terminal blocks for 24 V and 230 V.
504 x 489 x 120 12
WPM EconR 358380 4015627358386
Heat pump manager expansion modules
NWPM
EWPM
The NWPM expansion module acts as an interface between the heat pump manager and an Ethernet network. This extension allows the
remote setting and remote monitoring of the heat pump. A PC with a network card or a home network is required for this. The module
can record and save data. This extension is independent of the operating system. Data exchange with a KNX/EIB bus system, and the
connection of the heat pump manager to a building management system is provided via the EWPM extension module. This extension
makes it possible to set and monitor the heat pump via an installation bus.
Order reference Art.-no. For device type Features
NWPM 356960
WPM 2004 / 2006 / 2007
WPM EconPlus
Heat pump manager expansion module for connection
to an Ethernet network.
EWPM 356970
WPM 2006 / 2007
WPM EconPlus
Heat pump manager expansion module for connection
to the KNX/EIB bus.
LWPM 410 339410
WPM 2006 / 2007
WPM EconPlus
Expansion module (RS485) for the heat pump manager
for data transfer via Modbus interface protocol.
RWPM 363370
WPM 2006/2007
PKS 14/25 Econ
WPM Econ PK
Smart RTC (Room Temperature Controller)
Expansion module for heat pump manager for the
connection of a Smart-RTC (reference room controller),
a PKS 14/25 Econ passive cooling station or WPM Econ
PK to a WPM 2006/2007/Econ.
Expansion modules can be used from software version H_H5x onwards.
The heat pump manager only has one slot for NWPM, EWPM or LWPM 410 expansion cards. Parallell operation with several cards is not possible.
NWPM 356960 4015627356962
EWPM 356970 4015627356979
LWPM 410 339410 4015627339415
RWPM 363370 4015627363373
Accessories for heat pumps for heating purposes
Thermal energy meter
Connection to the heat pump manager
WMZ ..
Thermal energy meter, consists of a hydraulic assembly for flow and return (heating circuit) and electronic flow rate and temperature
detection. Low pressure drop thanks to flow measurement via Kármán vortex street in the flow and integrated temperature sensor in
the return (immersion sleeve). Electronics module for connection to the heat pump manager with separate evaluation for preparation of
heating water, domestic hot water (exception: compact heat pumps) and swimming pool water. Transitional screw connections for direct
connection of the WMZ 25 to the KPV 25/DDV 25 or of the WMZ 32 to the DDV 32 included in the scope of supply.
Order reference Art.-no. Nominal width Features Weight
kg
WMZ 25 358220
25 For volume flows of 0.5–2.5 m
3
/h 2.1
WMZ 32 358810
32 For volume flows of 1.0–5.0 m
3
/h 3 .0
Note: The thermal energy meter complies with the quality requirements of the BAFA (= German Federal Office of Economics and Export Control)
market incentive programme subsidizing efficient heat pumps (max. measurement tolerance ± 30 %). The thermal energy meter is not subject to
obligatory calibration, and can thus not be used for the heating cost billing procedure!
WMZ 25 358220 4015627358225
WMZ 32 358810 4015627358812
WPM EconR.