Technical data

www.dimplex.de/en
54
2012
Reference room regulation
Smart RTC (Room Temperature Controller)
RT Econ U
The reference room controller measures the temperature difference between the actual room temperature and the set temperature,
and communicates this to the heat pump manager. The return set temperature is calculated on the basis of this difference. The ~230 V
voltage supply (2-core) and the bus cable (2-core, screened) must be provided by the customer.
Additional functions:
- ‚Operating mode‘ button - switches between automatic and summer operating mode
- ‚Rapid heating‘ button - 20, 40 and 60-minute rapid heating (blocks domestic hot water)
- Warning signal displayed if a heat pump fault occurs
Order reference Art.-no. For device type Features Width x Height x Depth
mm
RT Econ U 362660
HPK ..TEW
LI ..TU
SI 6 - 18TU
WI 10 - 14TU
Flush-mounting version 86 x 86 x 28
RT Econ A 363340
Surface-mounting version 143 x 86 x 36
The reference room must be a living area which is permanently heated.
The RWPM interface card and a software version of L04 onwards must be installed to use the smart-RTC.
RT Econ U 362660 4015627362666
RT Econ A 363340 4015627363342
Solar controller for heat pump manager
WPM Econ SOL
Wall-mounted solar controller with temperature sensors for recording the flow and return temperatures. The extension module is con-
nected to the existing heat pump manager and provides the additional inputs and outputs required for solar control. Can be used with
a heat pump heating system with solar infeed in a 1 cylinder system - 1 collector field and one tank/cylinder (buffer tank, domestic hot
water cylinder, combo tank or combination tank). Graphic display on the heat pump manager with display of the cylinder temperature
and collector temperature. Adjustable collector cooling function, maximum cylinder temperature, switch-on/switch-off temperature
differences and pump kick function for optimum, efficient operation. Combination of the WPM Econ SOL solar controller with the heat
pump manager requires at least software version J_01. Delivery includes the PT 1000 temperature sensors and NTC 10.
Order reference Art.-no. For device type Features Width x Height x Depth
mm
WPM Econ SOL 363950
WPM EconPlus
WPM EconPlus-E
WPM EconR
2 inputs: Temperature detection for collector (PT 1000)
and solar cylinder (NTC-10), 1 output: Switching output for
brine pump (maximum switching capacity 400 W [230 V]).
200 x 489 x 120
PT 1000 364290
WPM Econ SOL
BWP 30HS
BWP 30HSD
Temperature sensor for registering solar collector tem-
peratures (1000 Ω/0 °C), diameter (Ø) 6 mm, cable length
1.5 m, sensor lead can be extended up to 100 m with a
cable cross-section of 1.5 mm².
The software version „J“ or onwards and the RWPM expansion modules are required for the combination of the heat pump manager WPM 2006/2007
WPM Econ SOL 363950 4015627363953
PT 1000 364290 4015627364295
Accessories for heat pumps for heating purposes
General accessories for heat pump managers
AP PGD
FG 3115
RBG WPM
Order reference Art.-no. Short text Features
AP PGD 356570
Remote control for
WPM 2006/2007/EconPlus/R
For connection to the wall-mounted WPM 2006 heat pump manager
with integrated display or as an additional remote control for WPM
2007/EconPlus/R.The remote control has an LCD with identical menu
navigation and backlight. The AWPM 900 connecting line must be
ordered separately.
AWPM 900 340210
Connection line for AP PGD
Heat pump manager/remote control connecting cable, 6-core. Can
also be used as a connection cable for the removable control panel
of the WPM 2007. (Length 15 m)
FG 3115 336620
External temperature sensor
with casing
Standard NTC-2 temperature sensor (2.43 kOhm/20 °C) according to
DIN 44574 with weather proof casing for surface mounting, terminal
connection.
RBG WPM 339700
Swimming pool/remote fault
indicator relay module
For connecting the swimming pool circulating pump (M19) and the
output of a 230 V signal if a system fault occurs (not required for
heating and cooling systems and WPM EconPlus).
AP PGD 356570 4015627356573
AWPM 900 340210 4015627340213
FG 3115 336620 4015627336629
RBG WPM 339700 4015627339705