Technical data
www.dimplex.de/en
57
2012
Fan convectors
SmartRad fan convectors
Casing colour white (similar to RAL 9010)
Connection voltage 1/N/PE ~230 V, 50 Hz
Fan convectors heating
SmartRad
SRX ...M
Wall-mounted Smart Rad fan convector with integrated electronic thermostat. Manual and automatic operation, maximum fan level can
be preset; automatic regulation of the 3 fan levels according to heat consumption. Water connection can be on the left or right. The con-
vectors can be used from a flow temperature of min. 25 °C; they can thus be integrated directly into an underfloor heating circuit (flow
temperature min. 14 °C, max. 85 °C) without an additional mixer. Rated power corresponds to the 2nd fan level – the 3rd fan level serves
as a boost function and increases the rated power by approximately 39%. Heating and lowering times as well as frost protection can be
individually adjusted using various RX or RMT2 programming cassettes (special accessory) which can be inserted into the device.
Order reference Art.-no. Rated power
(35 °C flow/
30 °C return
temperature)
W
Rated power
(45 °C flow/
40 °C return
temperature)
W
Rated power
(55 °C flow/
47 °C return
temperature)
W
Air volume
flow
m³/h
Width x Height x
Depth
mm
Weight
kg
SRX 080M 359080
358 695 956 125 503 x 530 x 145 13.5
SRX 120M 359090
561 1119 1541 190 670 x 530 x 145 17 .0
SRX 140M 359100
631 1329 1828 225 740 x 530 x 145 18 .0
SRX 180M 359110
893 1760 2424 300 911 x 530 x 145 22 .0
SRX 080M 359080 5011139359087
SRX 120M 359090 5011139359094
SRX 140M 359100 5011139359100
SRX 180M 359110 5011139359117
Fan convectors for heating/cooling
SRX ..CM
Smart Rad wall-mounted fan convector for heating and cooling with integrated electronic thermostat. Automatic operation, maximum
fan level can be preset; automatic switching between heating and cooling in automatic mode/regulation of 3 fan levels according to
heat consumption. Water connection for flow and return (external diameter 15 mm) possible on the right or left. Hose connection
(length 2 m) for draining condensate that forms during cooling operation. The convectors can be operated with a minimum flow tempe-
rature of 25 °C in heating operation (without an additional mixer for underfloor heating circuits) and a maximum flow temperature of
17 °C in cooling operation (minimum flow temperature 14 °C, maximum flow temperature 85 °C). Rated power corresponds to the 2nd
fan level – the 3rd fan level serves as a boost function and increases the rated power by approximately 39%. Heating and lowering times
as well as frost protection can be individually adjusted using various RX or RMT 2 programming cassettes (special accessory) which can
be inserted into the device.
Order reference Art.-no. Rated power
(35 °C flow/30 °C
return temperature)
W
Rated power
(45 °C flow/40 °C
return temperature)
W
Cooling
capacity
7/12 °C
W
Air volume
flow
m³/h
Width x Height x
Depth
mm
Weight
kg
SRX 70CM 363990
271 540 410 125 503 x 530 x 145 15
SRX 120CM 364000
595 1180 959 225 740 x 530 x 145 19
SRX 160CM 364010
801 1631 1225 300 911 x 530 x 145 23
SRX 70CM 363990 4015627363991
SRX 120CM 364000 4015627364004
SRX 160CM 364010 4015627364011
Programming cassette EPX, GFP, SRX convectors
RX PW 1
RX TI RB
Order reference Art.-no. Features
RX TI 24 RXTI24
24 h programming cassette with LCD, connectable to EPX wall convectors and SRX fan convectors.
Four ON and OFF times freely programmable, backlit display, key lock. Where several devices are
connected using a control line, a programming cassette can be used to control these devices. Devices
from the FPE, GPE, GFP, KSE and KLE series can also be connected to the control line.
RX PW 1 RXPW1
Week programming cassette with LCD, connectable to EPX wall convectors and SRX fan convectors.
Up to four programs can be set for a weekend block (Sat-Sun) or a workday block (Mon-Fri), the ON
and OFF times are then set. With backlit display and key lock. Where several devices are connected
using a control line, a programming cassette can be used to control these devices. Devices from the
FPE, GPE, GFP, KSE and KLE series can also be connected to the control line.
RX TI RB RXTIRB
Limited specified heating period; programming cassette for setting a heating period from 0.5 h to 4.0 h,
adjustable in 0.5 hour increments, when the specified heating period ends, the device shuts off or
switches to frost protection mode. Where several EPX devices or SRX fan convectors are connected
using a control line, a programming cassette can be used to control these devices. Devices from the
FPE, GPE, GFP, KSE and KLE series can also be connected to the control line.
RX TI 24 RXTI24 5011139020673
RX PW 1 RXPW1 5011139020680
RX TI RB RXTIRB 5011139020703
Programming cassette RMT
Incl. master function
RMT 2
Order reference Art.-no. Features
RMT 2 362920
Programming cassette connectable to radiant panel heaters and convectors of the GPE, GFP, FPE, EPX,
KSE and KLE series or fan convectors of the SRX series. Clearly laid out LCD; seven specified programs
and an individual program to set the heating and lowering times which can be assigned for each
weekday. Where several ecocomfort devices are used together with a common control line,
a programming cassette can be used to control up to 20 devices.
RMT 2 362920 4015627362925