Technical data
www.dimplex.de/en
58
2012
Heat pump - air/waste heat as heat source
Domestic hot water heat pump –
heat source indoor air/cellar air/outside air
Domestic hot water temperature up to max. 60 °C
Lower operating limit heat source (heating operation) 8 °C
Upper operating limit heat source (heating operation) 45 °C
Domestic hot water heat pump
Additional heat exchanger with solar function
BWP 30HS
Heat pump for domestic water heating, with LCD and extensive control functions (e. g. fast heating button, solar control, time program
for increasing the solar energy output by blocking domestic hot water preparation). Digital input for the use of privately generated elec-
tricity through combination with photovoltaic systems. EC radial fan, exhaust air and extract air stubs for optional connection of a duct
system with a maximum length of 10 m, mean heat pump output 1870 W (A15/W45), domestic hot water temperature selectable during
heat pump operation (25–60 °C); heating up to 65 °C possible via time programs with standard heating element (1.5 kW), refrigerant
designation R 134a. Steel cylinder with a usable capacity of 290 l, enamelled according to DIN 4753, protection anode against corro-
sion, integrated additional heat exchanger (approx. 1.45 m² for the connection of an external heat generator (e. g. boiler or solar energy
system), cladding tube for external cylinder sensor, digital output for controlling an external loading pump. Foil cladding colour white
(similar to RAL 9003), design front panel and cover white aluminium (similar to RAL 9006).
Order reference Art.-no. Connection voltage COP (EN 255) heat-up process
15 °C to 45 °C
Width x Height x Depth
mm
Weight
kg
BWP 30HS 360070
1/N/PE ~230 V, 50 Hz 3.7 700 x 1710 x 790 150
Nipple size DN 160, connection e. g. with SF R 162510 air hose or BGN 160.
To prevent an air short circuit, a room height of approx. 2.5 m is necessary for free blowing systems. The minimum height of the installation room
is reduced to approximately 2 m by installing a pipe bend on the air outlet side, or by connecting the system to an air duct. The PT 1000 collector
sensor required for solar control must be ordered as a special accessory. The maximum domestic hot water temperature reachable and the lower
operating limit vary by ±2 K due to component tolerances.
BWP 30HS 360070 4015627360075
Domestic hot water temperature up to max. 60 °C
Lower operating limit heat source (heating operation) -8 °C
Upper operating limit heat source (heating operation) 45 °C
Domestic hot water heat pump with defrosting
Additional heat exchanger with solar function
BWP 30HSD
Heat pump for domestic water heating, with LCD and extensive control functions (e. g. fast heating button, solar control, time program
for increasing the solar energy output by blocking domestic hot water preparation). Digital input for the use of privately generated
electricity through combination with photovoltaic systems. EC radial fan, exhaust air and extract air stubs for optional connection of a
duct system with a maximum length of 10 m, mean heat pump output 1870 W (A15/W45), domestic hot water temperature selectable
during heat pump operation (25–60 °C); heating up to 65 °C possible via time programs with standard heating element (1.5 kW), refrige-
rant designation R 134a. Extended operating limits via active defrosting when ice forms on the evaporator. Steel cylinder with a usable
capacity of 290 l, enamelled according to DIN 4753, protection anode against corrosion, integrated additional heat exchanger (approx.
1.45 m² for the connection of an external heat generator (e. g. boiler or solar energy system), cladding tube for external cylinder sensor,
digital output for controlling an external loading pump. Foil cladding colour white (similar to RAL 9003), design front panel and cover
white aluminium (similar to RAL 9006).
Order reference Art.-no. Connection voltage COP (EN 255) heat-up process
15 °C to 45 °C
Width x Height x Depth
mm
Weight
kg
BWP 30HSD 363620
1/N/PE ~230 V, 50 Hz 3.7 700 x 1710 x 790 150
Nipple size DN 160, connection e. g. with SF R 162510 air hose or BGN 160.
To prevent an air short circuit, a room height of approx. 2.5 m is necessary for free blowing systems. The minimum height of the installation room
is reduced to approximately 2 m by installing a pipe bend on the air outlet side, or by connecting the system to an air duct. The PT 1000 collector
sensor required for solar control must be ordered as a special accessory. The maximum domestic hot water temperature reachable and the lower
operating limit vary by ±2 K due to component tolerances.
BWP 30HSD 363620 4015627363625
Solar package (2 collectors) without solar controller
For domestic hot water heat pump BWP 30HS/HSD
SOLP 2 OR ..
Optimum solar package for BWP 30HS/HSD to support domestic hot water preparation for a household containing 2-4 people.
Solar regulation is via the domestic hot water heat pump (Connection PT 1000 sensor).
• 2 x SOLCU 180 solar controller
• 1 x SOLPU S solar station
• 1 x SOLVK 1 expansion vessel connection
• 1 x SOLEV 12 expansion vessel
• 1 x SOLHT 20 heat transfer fluid
• 1 x basic set for collector installation
• 1 x expansion set for collector installation
• 1 x PT 1000 solar sensor
Order reference Art.-no. Roof mounting kit
SOLP 2 OR PA 365410
Frankfurt tile
SOLP 2 OR BA 365420
Plain tile
SOLP 2 OR WA 365430
Corrugated sheet
SOLP 2 OR FA 365440
Free standing
SOLP 2 OR PA 365410 4015627365414
SOLP 2 OR BA 365420 4015627365421
SOLP 2 OR WA 365430 4015627365438
SOLP 2 OR FA 365440 4015627365445
Domestic hot water temperature up to max. 60 °C
Lower operating limit heat source (heating operation) 8 °C
Upper operating limit heat source (heating operation) 35 °C
Domestic hot water heat pump with foil cladding
With air duct connection
BWP 30HM
Insulated foil cladding, radial fan, exhaust air and extract air stubs for optional connection of a duct system with a maximum length of
10 m, infinitely variable hot water temperature for total volume of 300 l, switches for heat pump and heating element, steel cylinder en-
amelled according to DIN 4753, protection anode against corrosion, mean heat pump output 1870 W, hot water temperature selectable
during heat pump operation (25–60 °C), heating up to 65 °C with standard heating element (1.5 kW) possible, can controlled manually or
remotely using an external timer, refrigerant designation R134a, colour white (similar to RAL 9003).
Order reference Art.-no. Connection voltage COP (EN 255) heat-up process
15 °C to 45 °C
Width x Height x Depth
mm
Weight
kg
BWP 30HM 364840
1/N ~230 V, 50 Hz 3.5 700 x 1710 x 770 135
Nipple size DN 160, connection e. g. with SF R 162510 air hose or BGN 160.
The maximum domestic hot water temperature reachable and the lower operating limit vary by ±2 K due to component tolerances. To prevent an
air short circuit, a room height of approx. 2.5 m is necessary for free blowing systems. The minimum height of the installation room is reduced to
approximately 2 m by installing a pipe bend on the air outlet side, or by connecting the system to an air duct.
BWP 30HM 364840 4015627364840