Technical data
www.dimplex.de/en
59
2012
Heat pump - air/waste heat as heat source
Domestic hot water temperature up to max. 60 °C
Lower operating limit heat source (heating operation) 8 °C
Upper operating limit heat source (heating operation) 35 °C
Domestic hot water heat pump with foil cladding
Air duct connection and additional heat exchanger
BWP 30HMW
Insulated foil cladding, radial fan, exhaust air and extract air stubs for optional connection of a duct system with a maximum length of
10 m, infinitely variable hot water temperature for usable capacity of 290 l, switches for heat pump, heating element and second heat
generator, steel cylinder enamelled according to DIN 4753, protection anode against corrosion, mean heat pump output 1870 W, hot
water temperature selectable during heat pump operation (25–60 °C), heating up to 65 °C with standard heating element (1.5 kW) pos-
sible, can be either controlled manually or remotely using an external timer, integrated additional heat exchanger (approx. 1.45 m² ) for
connecting an external heat generator (e. g. , boiler or solar installation), cladding tube for external cylinder sensor, connection option
for an external block of heat pump operation, relay output for controlling an external loading pump, refrigerant designation R134a,
colour white (similar to RAL 9003).
Order reference Art.-no. Connection voltage COP (EN 255) heat-up process
15 °C to 45 °C
Width x Height x Depth
mm
Weight
kg
BWP 30HMW 365150
1/N/PE ~230 V, 50 Hz 3.5 700 x 1710 x 770 150
Nipple size DN 160, connection e. g. with SF R 162510 air hose or BGN 160.
The maximum domestic hot water temperature reachable and the lower operating limit var
y by ±2 K due to component tolerances. To prevent an
air short circuit, a room height of approx. 2.5 m is necessary for free blowing systems. The minimum height of the installation room is reduced to
approximately 2 m by installing a pipe bend on the air outlet side, or by connecting the system to an air duct.
BWP 30HLW 351380 4015627351387
BWP 30HMW 365150
Special accessories for domestic hot water heat pumps
BGN 160
Order reference Art.-no. Short text Features Weight
kg
SVK 852 326660
Safety valve
combination
For the cold water connection of domestic water cylinders to the
supply network according to DIN 1988. 1“ external thread connec-
tion; DN 20, 8 bar, yellow.
1.5
BGN 160 365170
Bend (160 mm, 90°)
Bend pressed, sheet steel smooth. Bush to nipple design for direct
installation on a Dimplex domestic hot water heat pump. With pleat
for customer installation of a round gasket.
0.9
SF R 162510 359620
Sonoflex pipe
Flexible round aluminium ventilation tube, 4 layers, with 25 mm
thermal insulation and vapour block (length 10 m)
external diameter = nominal width + 50 mm.
6.1
SF SD 165015 360780
Sound damper Internal diameter: 160 mm/ external diameter: 260 mm 0.7
PT 1000 364290
Solar sensor
Temperature sensor for registering solar collector temperatures
(1000 Ω/0 °C), diameter (Ø) 6 mm, cable length 1.5 m, sensor lead
can be extended up to 100 m with a cable cross-section of 1.5 mm².
The technical data for the air circuit components can be found in the ventilation technology section.
SVK 852 326660 4015627326668
BGN 160 365170 4015627365179
SF R 162510 359620 4015627359628
SF SD 165015 360780 4015627360785
PT 1000 364290 4015627364295
Domestic hot water heat pumps – heat source indoor air/exhaust air
Domestic hot water temperature up to max. 60 °C
Lower operating limit heat source (heating operation) 15 °C
Upper operating limit heat source (heating operation) 35 °C
Domestic hot water heat pump with foil cladding
For using indoor air
BWP 20A
Domestic hot water heat pumps for using 20 °C indoor air for domestic hot water preparation, installation dimension 60 cm; Insulated
foil cladding, radial fan, exhaust air and extract air stubs for optional connection of a duct system with a maximum length of 10 m, infini-
tely variable hot water temperature for total volume of 200 l, switch for continuous fan operation, steel cylinder enamelled according to
DIN 4753, protection anode against corrosion, mean heat pump output 910 W, domestic hot water temperature selectable during heat
pump operation (23 °C to 60 °C), heating up to 65 °C with standard heating element (1.5 kW) possible, can be either manually controlled
or remote controlled, for example, using an external timer, refrigerant designation R134a, colour white (similar to RAL 9003).
Order reference Art.-no. Connection voltage COP (EN 255) heat-up process
15 °C to 45 °C
Width x Height x Depth
mm
Weight
kg
BWP 20A 358230
1/N/PE ~230 V, 50 Hz 3.3 550 x 1700 x 550 96
DN 125 extract air stubs for optional connection to an exhaust air system.
The maximum domestic hot water temperature reachable and the lower operating limit var
y by ±2 K due to component tolerances.
BWP 20A 358230 4015627358232
Accessories for DN 125 hot water heat pumps
SF R
BGN 125
Order reference Art.-no. Short text Features Weight
kg
SF R 122510 359610
Sonoflex pipe
Flexible round aluminium ventilation tube, 4 layers, with 25 mm
thermal insulation and vapour block (length 10 m)
external diameter = nominal width + 50 mm.
4.4
BGN 125 365160
Bend (125 mm, 90°)
Bend pressed, sheet steel smooth. Bush to nipple design for direct
installation on a Dimplex domestic hot water heat pump. With
pleat for customer installation of a round gasket.
0.6
SF R 122510 359610 4015627359611
BGN 125 365160 4015627365162