Technical data
www.dimplex.de/en
64
2012
Solar domestic hot water cylinders
Solar domestic hot water cylinders
For heat pumps
WWSP 432 SOL
Solar domestic hot water cylinder made of steel (special inside enamelling) with protection anode, two integrated bare-tube heat
exchangers for solar and heating. Thanks to the temperature stratification, even small solar gains are sufficient to feed energy into the
lower cold water section of the cylinder. The upper part of the cylinder is kept at the comfort temperature. Thermometer, polyuretha-
ne insulation for low standby losses, colour white, flange TK 150/DN 110. An NTC 10 and an NTC 2 sensor are included in the scope of
supply.
Permissible operating pressure 10 bar;
Order reference Art.-no. For device type Features Diameter x Height
mm
Weight
kg
WWSP 432 SOL 361080
up to LI 20
excluding LI 15/16,
up to LA 22
excluding LA 16,
up to SI 11
up to WI 14
400 l nominal capacity, 346 l usable capacity,
3.2 m² heat exchange surface (heating), 1.3 m²
heat exchange surface (solar), 2.9 kWh/24 h
standby loss, 1 1/4“ solar and heating connec-
tions, 1“ domestic hot water connection, 3/4“
circulation connection
700 x 1631 182
WWSP 540 SOL 361090
up to LI 28
excluding LIH 26TE,
up to LA 28
up to SI 30
up to WI 22
500 l nominal capacity, 427 l usable capacity,
4.0 m² heat exchange surface (heating), 1.6 m²
heat exchange surface (solar), 3.2 kWh/24 h
standby loss, 1 1/4“ solar and heating connec-
tions, 1“ domestic hot water connection,
3/4“ circulation connection
700 x 1961 218
WWSP 540 SOL not suitable for SI 22TU
WWSP 432 SOL 361080 4015627361089
WWSP 540 SOL 361090 4015627361096
Solar domestic hot water cylinders
For conventional heating
CWWSP 308 SOL
Solar domestic hot water cylinder made of steel (special inside enamelling) with protection anode, two integrated bare-tube heat
exchangers for solar and heating. Thanks to the temperature stratification, even small solar gains are sufficient to feed energy into the
lower cold water section of the cylinder. The upper part of the cylinder is kept at the comfort temperature. Thermometer, polyuretha-
ne insulation for low standby losses, colour white, flange TK 150/DN 110. An NTC 10 and an NTC 2 sensor are included in the scope of
supply.
Permissible operating pressure 13 bar;
Order reference Art.-no. Features Diameter x Height
mm
Weight
kg
CWWSP 308 SOL 361120
300 l nominal capacity, 290 l usable capacity, 0.8 m² heat exchange
surface, 1.55 m² heat exchange surface (solar), 2.6 kWh/24 h stand-
by loss, 1“ solar and heating connections, 1“ domestic hot water
connection, 3/4“ circulation connection
600 x 1834 113
CWWSP 411 SOL 361130
400 l nominal capacity, 380 l usable capacity, 1.05 m² heat
exchange surface (heating), 1.8 m² heat exchange surface (solar),
2.6 kWh/24 h standby loss, 1“ solar and heating connections, 1“
domestic hot water connection, 3/4“ circulation connection
700 x 1631 133
CWWSP 308 SOL 361120 4015627361126
CWWSP 411 SOL 361130 4015627361133
Solar station for domestic hot water
Solar back-up for domestic hot water preparation
SST 25
DWUS 25 SOL
Heat exchanger solar station consisting of a solar separation system and pump assembly with insulation jackets for integrating solar
installations up to 10 m² into the domestic hot water heating system. The solar station enables efficient hot water heating via the heat
pump and the solar installation. Modules with a primary and secondary circuit consisting of: 2 circulating pumps (WILO- STAR-ST 25/6
and STAR-RS 24/4); 4 ball valves 1“ with thermometer, return inhibitor, safety module with safety valve and 0–10 bar pressure gauge,
connection options for expansion vessel (solar controller not included in scope of supply).
Order reference Art.-no. Width x Height x Depth
mm
Weight
kg
SST 25 348430
320 x 1050 x 320 19
SST 25 348430 4015627348431
Solar collectors and accessories
Solar reversing valve
Three-way reversing valve for switching from solar energy systems to domestic hot water preparation or supplementary heating. Motor
operated for short switching times (set time open 12 s, set time closed 6 s); for a maximum volume flow of 2 m²/h; maximum differential
pressure 0.6 bar; temperature operating range for solar energy systems from -20–160 °C; maximum ambient temperature 50 °C.
Order reference Art.-no. Solar connection
˝
Nominal width
DWUS 25 SOL 363780
1 D N 2 5
DWUS 25 SOL 363780 4015627363786