Technical data
www.dimplex.de/en
9
2012
Air-to-water heat pump package solution
Heating package
Heat pump and HPK 200S hydraulic tower
HPL ...
The hydraulic tower (W = 680 mm; H = 1660; D = 775) with integrated WPM 2006 plus controller facilitates quick and easy connection
of an air-to-water heat pump installed outdoors to a heating system with an unmixed heating circuit. The following components are
mounted and wired in a space saving way in the white sheet steel casing, which has a red-brown design screen:
• Switchable pipe heater (2/4/6 kW)
• Buffer tank (200 l) with installation option for an additional immersion heater (up to CTHK 634)
• Electronically regulated circulating pump (energy class A) for unmixed heating circuits (consumer circuit)
• Expansion vessel (24 l) with safety module
• The hydraulic isolation of the generator circuit and the consumer circuit is carried out via two differential pressureless manifolds
(bypass pipes), which are each fitted with a check valve.
To reduce the run times, the unregulated auxiliary circulating pump in the generator circuit is only operated when the compressor is
running and when there is a risk of frost. The uniform flow through the buffer tank connected in series extends the runtimes of the com-
pressor and ensures the required heating water flow rate in all operating modes. Integration option for a domestic hot water load pump
(inside micrometer 180 mm, DN 25) and an additional mixed heating circuit (special accessories).
The EVL ... electric cable for connecting the heat pump and the hydraulic tower must be ordered separately.
Order reference Art.-no. Features Weight
kg
HPL 11MAS 363970
LA 11MAS heating package and HPK 200S hydraulic tower 376
HPL 16MAS 363980
LA 16MAS heating package and HPK 200S hydraulic tower 414
HPL 11TAS 362690
LA 11TAS heating package and HPK 200S hydraulic tower 380
HPL 16TAS 362700
LA 16TAS heating package and HPK 200S hydraulic tower 416
HPL 20AS 356750
LA 20AS heating package and HPK 200S hydraulic tower 471
HPL 24AS 356760
LA 24AS heating package and HPK 200S hydraulic tower 538
HPL 28AS 356770
LA 28AS heating package and HPK 200S hydraulic tower 542
HPL 8PMS 363310
LA 8PMS heating package and HPK 200S hydraulic tower 419
HPL 11PS 356790
LA 11PS heating package and HPK 200S hydraulic tower 446
HPL 14PMS 363830
LA 14PMS heating package and HPK 200S hydraulic tower 443
HPL 17PS 356800
LA 17PS heating package and HPK 200S hydraulic tower 517
HPL 22PS 356810
LA 22PS heating package and HPK 200S hydraulic tower 547
HPL 26PS 356820
LA 26PS heating package and HPK 200S hydraulic tower 558
HPL 26HS 356840
LA 26HS heating package and HPK 200S hydraulic tower 605
The hydraulic tower cannot be ordered separately due to the integrated heat pump manager. For every combinable heat pump, there is a sales
package consisting of the heat pump without the controller and the hydraulic tower.
The technical data for the heat pump can be found on the following pages.
If the heating water connection lines are more than 10 m long, the free compression values stated in the device information must be observed
(minimum pipe diameter for volume flows of more than 1.5 m³/h: DN 32).
HPL 11MS 356850 4015627356856
HPL 16MS 356860 4015627356863
HPL 11MAS 363970 4015627363977
HPL 16MAS 363980 4015627363984
HPL 11TAS 362690 4015627362697
HPL 16TAS 362700 4015627362703
HPL 20AS 356750 4015627356757
HPL 24AS 356760 4015627356764
HPL 28AS 356770 4015627356771
HPL 8PMS 363310 4015627363311
HPL 11PS 356790 4015627356795
HPL 14PMS 363830 4015627363830
HPL 17PS 356800 4015627356801
HPL 22PS 356810 4015627356818
HPL 26PS 356820 4015627356825
HPL 26HS 356840 4015627356849
Air-to-water heat pump for outdoor installation
Hydro Tower with external heat pump manager
Compact installation for heating and domestic hot water preparation
HWK 332
The Hydro Tower enables the fast and simple connection of a heat pump for heating purposes to a heating system with an unmixed
heating circuit. The heat pump manager included in the scope of supply of the heat pump is used for the electronic control of the com-
ponents (external wiring required). The following components are installed in a space-saving way and wired ready for use:
• Switchable pipe heater (2/4/6 kW) for supplementary heating
• Buffer tank (100 l) with installation option for an additional immersion heater (up to CTHK 634)
• Domestic hot water cylinder 300 l with 3.2 m² tube heat exchanger and 1.5 kW flange heater for thermal disinfection
• Electronically regulated circulating pump (energy efficiency class A) wired ready to use for unmixed heating circuits (consumer circuit)
• Unregulated auxiliary circulating pump for generator circuit and domestic hot water loading pump
• The hydraulic isolation of the generator circuit and the consumer circuit is carried out via two differential pressureless manifolds
(bypass pipes), which are each fitted with a check valve.
To reduce the run times, the unregulated auxiliary circulating pump in the generator circuit is only operated when the compressor is
running and when there is a risk of frost. The uniform flow through the buffer tank connected in series extends the runtimes of the com-
pressor and ensures the required heating water flow rate in all operating modes. NTC-10M temperature sensor pre-installed, NTC-2M in
scope of supply.
Order reference Art.-no. For device type Width x Height x Depth
mm
Weight
kg
HWK 332 362360
LA 6 - 17TU, LA 11TAS(MAS), LA 8 - 22P(M)S
LI 9 / 11TES; LI 9 / 12TU
SIH 6 - 11TE; SI 6 - 11TU
WI 10 /14TU
710 x 1890 x 950 210
If the heating water connection lines are more than 10 m long, the free compression values stated in the device information must be observed
(minimum pipe diameter for volume flows of more than 1.5 m³/h: DN 32). When using the Hydro Tower with LA 8PMS or LA 11PS heat pumps, the
pre-mounted sensors must be replaced by the NTC-2 sensors included in the scope of supply.
HWK 332 362360 4015627362369