Hot-air curtain
Connection voltage 1/N/PE ~230 V, 50 Hz
Degree of protection IP 20
Protection class l
Air curtains AC…N
Electric operation
AC ... N
Mounting above doors or on ceilings, adjustable air outlet direction, 2 heating levels, 1 cold air level. Operated either on the device or
with a remote control (only AC 3RN). For door widths from 600 mm (AC 3 and AC 45) to 900 mm (AC 6).
Order reference Art.-no. Rated power
W
Air volume flow
m³/h
Max. tempera-
ture increase
K
Sound pressure
level in 3 m
dB (A)
Width x Height
x Depth
mm
Weight
kg
AC 3 N 348220
3000 212 42 50
605 x 214 x 135
5.1
AC 45 N 348230
4500 248 53 52 5.2
AC 6 N 348240
6000 446 40 57 905 x 214 x 135 7.2
AC 3 RN 348250
3000 212 42 50 605 x 214 x 135 5.3
AC 3 N 348220 4015627348226
AC 45 N 348230 4015627348233
AC 6 N 348240 4015627348240
AC 3 RN 348250 4015627348257
Connection voltage 3/N/PE ~400 V, 50 Hz
Protection class l
Air barrier CAB series
Electric operation
CAB 10 E V2
Mounting above doors, ceilings or hidden (optional installation kit needed), modular design allows simple placing of devices in a row,
adjustable direction of flow, 2 heating levels, cold air level, 2 ventilation levels, controllable using a wall-mounted low-voltage control or
by connecting to a building management system. A separate control panel allows regulation of up to 4 devices at a time, optional door
sensor switching. Installation height up to 2.7 m. Essential accessories: CAB C5 operator control. Accessories for combining up to
4 devices: CAB M1 V2 connection kit; Colour white, intake grid black. The connections between the operator panel and the hot-air cur-
tains and between the devices are established using a standard data cable (type CAT 5E or higher) – data cable not included in the scope
of supply.
Order reference Art.-no. Rated power
W
Air volume flow
m³/h
Max. tempera-
ture increase
K
Sound pressure
level in 3 m
dB (A)
Width x Height
x Depth
mm
Weight
kg
CAB 10E V2 117984
9000 1200
4 4
54 1057 x 262 x 316 25 .0
CAB 15E V2 117991
13500 1800 55 1557 x 262 x 316 36 .0
CAB 10E V2 117984 5011139117984
CAB 15E V2 117991 5011139117991
Connection voltage 3/N/PE ~400 V, 50 Hz
Protection class l
Air barrier DAB series
Electric operation
DAB 10 E V2
Mounting above doors, ceilings or hidden (optional installation kit needed), modular design allows simple placing of devices in a row,
adjustable direction of flow, 2 heating levels, cold air level, 2 ventilation levels, controllable using a wall-mounted low-voltage control or
by connecting to a building management system. A separate control panel allows regulation of up to 4 devices at a time, optional door
sensor switching. Installation height up to 4.0 m. Essential accessories: CAB C5 operator control. Accessories for combining up to
4 devices: CAB M1 V2 connection kit; Colour white, intake grid black. The connections between the operator panel and the hot-air cur-
tains and between the devices are established using a standard data cable (type CAT 5E or higher) – data cable not included in the scope
of supply.
Order reference Art.-no. Rated power
W
Air volume flow
m³/h
Max. tempera-
ture increase
K
Sound pressure
level in 3 m
dB (A)
Width x Height
x Depth
mm
Weight
kg
DAB 10E V2 118004
12000 3000 23 58 1060 x 360 x 390 39
DAB 15E V2 118011
18000 4000 26 59 1560 x 360 x 390 50
DAB 10E V2 118004 5011139118004
DAB 15E V2 118011 5011139118011
Connection voltage 1/N/PE ~230 V, 50 Hz
Protection class l
Air barrier CAB series
hot water operation
CAB 10 W V2
Hot water operation, mounting above doors, on ceilings or hidden (optional installation kit needed), modular design allows simple
placing of devices in a row, mounting height up to 2.7 m, adjustable direction of flow, 2 fan levels, controllable using wall-mounted
low-voltage control or by connecting to a building management system. A separate control panel allows regulation of up to 4 devices at
a time, optional door sensor switching. BEAB Intertek certification. Essential accessories: CAB C 6 operator control; for combining several
CAB M1 V2 devices. The connections between the operator panel and the hot-air curtains and between the devices are established
using a standard data cable (type CAT 5 or higher) - data cable not included in the scope of supply. Colour white, intake grid black. The
connections between the operator panel and the hot-air curtains and between the devices are established using a standard data cable
(type CAT 5E or higher) – data cable not included in the scope of supply.
Order reference Art.-no. Rated power
W
Air volume flow
m³/h
Max. tempera-
ture increase
K
Sound pressure
level in 3 m
dB (A)
Width x Height
x Depth
mm
Weight
kg
CAB 10W V2 118028
8500 1100 23 53 1057 x 262 x 316 25
CAB 15W V2 118035
12700 1700 22 54 1557 x 262 x 316 36
Rated output at 20 °C air intake temperature rated output at 80 °C flow temperature and 60 °C return flow temperature
CAB 10W V2 118028 5011139118028
CAB 15W V2 118035 5011139118035