Langbrook 5kW Clean Burn Stove (LBK5SE) Please hand these instructions to the stove user when installation is complete. Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of controls. Installation should only be carried out by a suitably qualified installer that is registered with HETAS (UK) or with the Irish Nationwide Fireplace Organisation (INFO). Installation must comply with Building Regulations.
1 B F C K (Dia) H G D A J E Table 1 - Dimensions A B C D E F G H J K Langbrook 5kw 600 500 30 250 105 368 23 110 472 127 Note: All Dimensions in mm. Dimensions stated may be subject to a slight ± variation. ( 25.4mm = 1”) Table 2 - Technical Specification Nominal heat output Efficiency CO Emission (@13% O2) Flue Gas Temp Flue Gas Mass Flow Langbrook 5kw Wood kW Solid Fuel (Ancit) kW 5.0 Wood % 77.0 Solid Fuel (Ancit) % 78.4 Wood % 0.32 Solid Fuel (Ancit) % 0.
4 3 Solid, non-combustible material e.g.
7 8 Seal gap with fire-proof lagging SEAL 150 max 150 max 9 10 B C D A CLOSURE PLATE
Langbrook 5kW Clean Burn Stove (LBK5SE) -1- IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE Important Safety Advice Please read these instructions carefully before installing or using this appliance. Failure to do so may result in damage to persons and property.
-2- Flue Deposits If the chimney was previously used as an open fire, it is possible that the higher flue gas temperatures generated by the stove may loosen deposits that were previously adhered to the inner surface of the flue pipe which could cause blockage of the flue pipe. We recommend that in this situation a second sweeping of the chimney should be carried out within one month of initial stove use after installation.
-3- with all windows and doors shut in the room where the appliance is fitted. If a ceiling fan is present it must be operated on max for the duration of the test. If there are any extraction fans in adjacent rooms these too must be operated on maximum setting during the test with the interconnecting doors open. If any spillage occurs, recheck the suitability of the flue system making sure there is adequate air supply to the room (as per Building Regulations).
-4- Safety Notes for Your Guidance Troubleshooting FIRES CAN BE DANGEROUS. Always use a fire guard in the presence of children, the elderly or the infirm. Inform all persons the dangers of high temperatures during operation of the appliance including the stove pipe. Use operating tools provided. 1. Poor heat output a. Stove too small for room: Seek advice from a Qualified Heating Engineer as to (kW) output required for the room size. As a guideline the volume of the room in cubic feet divided by 500; e.
-5- The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a designated smoke control area.
Langbrook 5kW (LBK5SE) 28 16 27 9 10 21 20 15 3 7 2 12 13 14 1 6 4 5 19 18 29 22 30 17 11 8 23 25 24 26 LANGBROOK 5KW STOVE (LBK5SE) - SPARE PARTS Item Description Part Number Item Description Part Number 1 DOOR 3011102 16 BAFFLE PLATE 3011117 2 DOOR HINGE 3011103 17 ASHPAN 3011118 3 HINGE MOUNT 3011104 18 PRIMARY AIR SLIDE 3011119 4 DOOR HANDLE 3011105 19 PRIMARY AIR HANDLE 3011120 5 HANDLE PIN 3011106 20 AIRWASH 3011121 6 DOOR GLASS 3011107 21 AIR
DIMPLEX MILLBROOK HOUSE GRANGE DRIVE HEDGE END SOUTHAMPTON SO30 2DF TEL: 0845 600 5111 FAX: 01489 773050 WEBSITE: www.dimplex.co.uk Republic of Ireland Tel: 01 842 8222 [c]A Division of GDC Group Ltd. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of GDC Group Ltd.