Installation and User’s Guide Models PLF3614-XS PLF4214-XS PLF5014-XS PLF6014-XS We value your feedback! Your input helps to create even better products and experiences. Share the warmth and leave a review. dimplex.com/sharethewarmth IMPORTANT SAFETY INFORMATION: Read this manual first before attempting to install or use this electric fireplace. Always comply with the warnings and safety instructions contained in this manual to prevent personal injury or property damage.
Table of Contents Contents Welcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 IMPORTANT INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 FCC Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Welcome Thank you and congratulations for choosing to purchase a Dimplex fireplace. Please carefully read and save these instructions. CAUTION: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, fire hazard and will void the warranty. Please record your model and serial numbers for future reference.
IMPORTANT INSTRUCTIONS When using any electrical appliance, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons. These precautions include: ⑧ Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, fire, or damage to the fireplace. ① Read all instructions before using this electric fireplace. ⑨ To prevent a possible fire, do not block air intakes or exhaust in any manner.
IMPORTANT INSTRUCTIONS FCC Compliance CAUTION: This unit has been tested and found to comply with the limits for Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Technical Specifications Electrical Rating Voltage: 120 V Power: 1500 W UL Listing File Number: E71416 Model Reference PLF3614-XS 6910470100 PLF4214-XS 6910470200 PLF5014-XS 6910470300 PLF6014-XS 6910470400 Product Dimensions 3 7/8" 99 mm Figure 1 A 19 1/2" 497 mm 12 5/8" 322 mm B Model 6 3 3/4" 97 mm A B PLF3614-XS 33 1/4" 845 mm 37 1/4" 946 mm PLF4214-XS 39 1/4" 997 mm 43 1/4" 1098 mm PLF5014-XS 47 1/4" 1201 mm 51 1/4" 1301 mm PLF6014-XS 57 1/4" 1455 mm 61 1/4" 1555 m
Package Contents Quantity Image Do not dispose of the suction cup after installation. Keep it in a secure location as it will be helpful for maintenance and service of the unit.
Package Contents Hardware Kit 8 Media Bed Brackets 2 2 2 2 Mirrored Glass Bracket 1 1 2 2 1" Wood Screws 5 5 5 5 Black Screws 7 7 10 10 Bubble Level 1 1 1 1 Wire Connector 3 3 3 3 www.dimplex.
Installation Placement This fireplace can be fully recessed into a wall with 2x4 framing or mounted on the wall. ! NOTE: It is recommended that the bottom of the unit be mounted between 20" (51 cm) and 40" (102 cm) from the ground to maintain an optimized viewing angle of the flame. WARNING: The top of the fireplace must be installed a minimum of 24" (61 cm) from the ceiling.
Installation Recessed Installation 1. Remove the side cover panels from the fireplace by removing the 5 screws on each of the cover panels (4 on the back of the fireplace, 1 on the bottom). (Figure 2) Figure 2 2. If a trimless installation is desired, remove preinstalled trim by removing the screws (number of screws will vary by model). (Figure 3) ! NOTE: The pre-installed trim helps conceal imperfections in the drywall edges against the fireplace and gives the fireplace a finished appearance.
Installation 9. Drive 4 screws through the mounting holes located on the inside sides of the firebox into the surrounding frame. (Figure 6) Figure 6 CAUTION: Ensure the air intake and heater exhaust are not obstructed in installation. These are located behind the front grill. 10. Follow the instructions for installing the mirrored glass, media bed, and front glass (pp. 14-15). Wall-mounted Installation Figure 7 1.
Installation Electrical Installation WARNING: The installation of the electric fireplace must comply with the applicable Local and/or National Electrical Codes and utility requirements. CAUTION: A dedicated, properly fused 15 Amp circuit is recommended, rated for 120 V. A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular basis when the heater is operating.
Installation Optional Plug Kit (PLFXSPLUG, sold separately) 1. 2. 3. 4. 5. 6. Remove the 3 screws that hold the electrical cover plate. (Figure 5, p.10) Connect the black L wire from the unit to the black wire of the plug kit. Connect the white N wire from the fireplace to the white wire from the plug kit. Connect green G wire from the fireplace to the green wire from the plug kit. Ensure all wire connections are tight.
Installation Figure 13 Mirrored Glass Installation 1. Attach the provided suction cup to the reflective side of the mirrored glass. Ensure the suction cup is securely attached. 2. Using the suction cup to assist, lift the mirrored glass and place it into the bottom crevice at an angle. 3. Tilt the glass up into position. The mirror will remain at a slight angle by design. (Figure 13) 4. Secure the mirror using the mirror retaining brackets and screws provided.
Installation Front Glass Installation Figure 17 1. Ensure there are no debris or finger prints on the mirrored glass or on the back of the front glass before you begin. 2. Secure the provided suction cup on the front glass, ensuring it cannot be pulled off. 3. Lift the glass using the suction cup, and align the 4 mounting brackets on the front glass with the corresponding slots on the fireplace. 4.
Operation General Operation WARNING : This electric firebox must be properly installed before it is used. ! NOTE: The element retains heat after shutdown. When the heat is turned Off, there is a 5-minute cool down period before the fan shuts off completely. ! NOTE: The fireplace will retain the previously used settings after a power interruption. Hidden Touch Controls The hidden touch controls are located on the upper right of the fireplace.
Operation Flame Speed Heat Heat Disable Press repeatedly to cycle through the 5 flame speeds. Press to turn the heat on or off. The fireplace will beep once and the remain on the display when activated. icon will The fireplace can be operated in heat only mode by turning off the flame and color effects. Press and hold the and the at the same time for 3 seconds to disable or enable the heat function. This action must be performed on the hidden touch controls.
Operation Factory Reset Press and hold and at the same time for 3 seconds to reset all the settings to factory default. This action will also disconnect the unit from the Wi-F network if connected. This action must be performed on the hidden touch controls. Resetting the Temperature Cutoff Switch Should the heater overheat, a manual limit cut-out will turn the unit off and it will not come back on without being reset. If the button on the unit is pressed, Err 1 will be displayed on the unit.
Maintenance Remote Control Battery Replacement Figure 20 1. Depress tab and pull out to release battery compartment on bottom of the remote control. 2. Correctly install one 3 Volt (CR2032 [longer life] or CR2025) battery in the battery compartment 3. Insert the battery compartment. Battery must be recycled or disposed of properly.
Troubleshooting Problem Display Cause Fireplace does not turn on with the manual touch controls N/A No incoming power Fireplace does not turn on with the remote control N/A The batteries in the remote control are dead or installed incorrectly --- Heater is disabled H-- Heater has been permanently disabled Heater does not turn on Normal operation — There is a 30-second delay before heater starts Heater is on, but there is no heat Circuit breaker trips or fuse blows when unit is turned on Pres
Wiring Diagrams PLF3614-XS PLF4214-XS 21
Wiring Diagrams PLF5014-XS PLF6014-XS 22 www.dimplex.
Warranty MULTI-FIRE® SL 2 YEAR LIMITED WARRANTY Section 1 Products to which this Limited Warranty Applies This Limited Warranty applies to your newly purchased Dimplex Electric Fireplace with Model Numbers PLF3614-XS, PLF4214-XS, PLF5014-XS, and PLF6014-XS. This Limited Warranty applies only to purchases made in any province of Canada except for Yukon Territory, Nunavut, or Northwest Territories or in any of the 50 States of the USA and the District of Columbia except for Hawaii and Alaska.
We value your feedback! Your input helps to create even better products and experiences. Share the warmth and leave a review. dimplex.com/sharethewarmth QR label For more information on the Flame Connect app, visit dimplex.com/fcapp 1-888-346-7539 | www.dimplex.com In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice.