Operating instructions

Operation - TI and TX Timer Models
Control of Output and Temperature (see Fig. 5)
The slide switch on the timer unit controls the electricity supply
to the heating elements on TI and TX models.
The switch marked I - II (half heat – full heat) provides a
choice of output as desired.
Thermostat Operation
- see above.
Using the Timer
The heater must be connected to the electricity supply for the
timer to operate. Set the timer by rotating the dial clockwise
until the correct time of day is indicated opposite the datum
mark (located at centre front of the timer - see Fig. 5).
‘OFF’ Position
Set the timer switch to
position. The timer operates but the
heater will not output any heat, as the electricity supply to the
heating elements has been disconnected.
Manual Operation
Set the timer switch to position. The heater will now
operate continuously under the control of the thermostat - see
‘Thermostat Operation’ above.
Automatic Operation
Set the timer switch to
position. The panel will now operate
during set ‘ON’ periods under the control of the thermostat.
To set the timers ‘ON’ and ‘OFF’ periods:
1. Using your nger tip or the tip of a
pencil, push in as many segments as
necessary around the dial, according
to the times you don’t require heat –
see Fig. 6. Each segment pushed
in switches the heater OFF for that
part of the hour. All other segments
will be ‘ON’.
2. You can select as many ‘ON’ periods as you like, within the
24-hour day. The settings will repeat every day until changed.
3. To change ‘ON’ and ‘OFF’ times, simply push in any ‘ON’
segments you wish to cancel and pull out new ‘ON’ segments
as required.
Note: On TI models each segment on the timer represents
20 mins.
TX Models
TX Models are tted with 7 day programmable timers. In all
other respects they are identical in installation and operation
to 24 hour timer operation on TI models.
1. Setting the Time
The current day and time is set by rotating the timer dial
clockwise until the correct day and time is indicated opposite
the datum mark.
2. Automatic Operation
Set the time switch to the
symbol. Select the days and
11
5
13
12
14
I
O
Fig. 5
Fig. 6
times you require the heater to come on by pulling out the
appropriate segments. Each segment represents a 2 hour 20
minute period for the day indicated. The timer may be set to
give as many ‘ON’ periods of any length required in multiples
of 2 hours and 20 minutes. The programme will repeat itself
every 7 days until changed.
The programme may be over-ridden at any time by switching to
or and can be reinstated by switching back to setting.
Safety - Overheat protection
For your safety this appliance is tted with a thermal cut-out.
In the event that the product overheats for some reason, the
cut-out prevents excessive temperatures on the product by
cutting the power to the heater. Once the heater has cooled
down, it will reset automatically, it will continue to cycle on and
off automatically until the reason for overheating is removed.
Cleaning
Before commencing cleaning, unplug the heater and allow
it to cool. Disconnect the electricity supply to the appliance.
The outside can be cleaned by wiping it over with a soft damp
cloth and then dried. Do not use abrasive cleaning powders or
furniture polish, as this can damage the surface nish.
To release heater from the wall bracket for cleaning or
redecoration, depress latch on both brackets (see Fig. 2) and
hinge forward.
Recycling
For electrical products sold within the European
Community.
At the end of the electrical products useful life
it should not be disposed of with household
waste. Please recycle where facilities exist.
Check with your Local Authority or retailer for
recycling advice in your country.
After Sales Service
If this product appears damaged when rst received or does not
function correctly contact us by email aftersales@dimplex.co.uk
or call 0844 879 3588 and we will be able to help. For ROI please
call 01 842 8222.
Do Not Return the product in the rst instance as this may delay
us providing you with a satisfactory service.
ACCIDENTAL DAMAGE IS NOT COVERED UNDER THE
WARRANTY.
Your product is guaranteed for two years from date of purchase. Within
this period we undertake to repair this product free of charge provided it
has been installed and operated in accordance with these instructions.
Should you require assistance with this product please go to www.
dimplex.co.uk and click on “Customer Support” or email us at
aftersales@dimplex.co.uk
Alternatively call our contact centre on 0844 879 3588 (UK only). This
is a Lo-call no. from a BT landline - other providers including mobile
phones may charge you more. For ROI please call 01 842 8222.
To assist you, we will need the following information: model no and
serial no (these can be found on the product), nature of the fault and
date of purchase. Please retain your receipt as proof of purchase.
Your rights under this guarantee are additional to your statutory rights,
which in turn are not affected by this guarantee.
Spares can be purchased online, go to www.dimplex.co.uk/
outlet_store