MODEL SF5601 PARTS & SERVICE MANUAL Formally Sold under 7400470100R00
Table of Contents OPERATION ......................................................................................................... 3 WIRING DIAGRAM ............................................................................................... 6 REPLACEMENT PARTS ...................................................................................... 6 TO REPLACE UPPER LIGHT BULBS.................................................................. 7 TO REPLACE LOWER LIGHT BULBS ..............................
SYMPHONY ELECTRIC FIREPLACE OPERATION This section will explain the function of each convent control. To access the controls, open the upper grill by pulling near the top, forward and down. A. MAIN ON/OFF SWITCH The on/off switch supplies power to all fireplace functions (heater & flame). B. FLAME SPEED CONTROL (not available on some models) Turn the flame speed control knob to adjust the flame speed to the desired level. C.
SYMPHONY ELECTRIC FIREPLACE OPTIONAL REMOTE CONTROL USAGE 1. Plug the fireplace into the outlet located on the side of the receiver. 2. Plug the receiver into the wall outlet. 3. Install a 9 volt battery into the transmitter. 4. Turn the fireplace main power switch to the ON position prior to using the remote control. 5. The remote control works up to 50 feet away. 6. Push the ON button to turn fireplace on, push the OFF button to turn the fireplace off.
SYMPHONY ELECTRIC FIREPLACE 5
WIRING DIAGRAM REPLACEMENT PARTS SF SERIES FIREPLACES SYMPHONY CATALOGUE NO. PART NO. MOD. LEVEL SF5601 6900240959 MOD C REPLACEMENT PART REPLACEMENT PART NO. 1. GLASS 6900100400RP 2. GRILL 6900080159RP 3. LOG SET 0437960100RP 4. MIRROR 5900060300RP 5. POWER ON/OFF SWITCH 2800070200RP 6. LIGHT DIMMER KNOB 8800000800RP 7. FLAME SPEED KNOB 8800000200RP 8. HEATER ON/OFF SWITCH 2800070200RP 9. THERMOSTAT KNOB 8800000300RP 10.THERMOSTAT 2300150100RP* 11.
SYMPHONY ELECTRIC FIREPLACE If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log exterior disappears.
SYMPHONY ELECTRIC FIREPLACE If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log exterior disappears.
SYMPHONY ELECTRIC FIREPLACE If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE MAIN ON/OFF SWITCH 1. Remove the firebox trim by placing your hand on the grill section, grasping the trim and pulling outwards releasing the retainer clips. 2.
SYMPHONY ELECTRIC FIREPLACE If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE LIGHT DIMMER SWITCH 1. Remove the firebox trim by placing your hand on the grill section, grasping the trim and pulling outwards releasing the retainer clips. 2.
SYMPHONY ELECTRIC FIREPLACE If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE FLAME SPEED CONTROL 1. Remove the firebox trim by placing your hand on the grill section, grasping the trim and pulling outwards releasing the retainer clips. 2.
SYMPHONY ELECTRIC FIREPLACE If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE FLAME MOTOR/FLAME ROD 1. Remove the firebox trim by placing your hand on the grill section, grasping the trim and pulling outwards releasing the retainer clips. 2.
SYMPHONY ELECTRIC FIREPLACE TO REPLACE FLAME MOTOR/FLAME ROD NOTE: Removal of the glass eases the installation of the bottom cover. 11. Remove the mounting screw in the center of the glass and remove the retainer bracket. 12. Remove the glass by lifting up from the bottom. 13. Reassemble in the reverse order as above.
SYMPHONY ELECTRIC FIREPLACE If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HEATER ON/OFF SWITCH 1. Remove the firebox trim by placing your hand on the grill section, grasping the trim and pulling outwards releasing the retainer clips. 2.
SYMPHONY ELECTRIC FIREPLACE If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HEATER THERMOSTAT CONTROL 1. Remove the firebox trim by placing your hand on the grill section, grasping the trim and pulling outwards releasing the retainer clips. 2.
SYMPHONY ELECTRIC FIREPLACE If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HEATER ASSEMBLY 1. Remove the firebox trim by placing your hand on the grill section, grasping the trim and pulling outwards releasing the retainer clips. 2.
SYMPHONY ELECTRIC FIREPLACE If the fireplace was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE THE POWER CORD 1. Remove the firebox trim by placing your hand on the grill section, grasping the trim and pulling outwards releasing the retainer clips. 2.
SYMPHONY ELECTRIC FIREPLACE TROUBLESHOOTING GUIDE APPEARANCE Problem Flame frozen. Probable Cause Loose wiring or defective flame motor. Solution Check all wiring for loose connections, repair/replace as necessary. If wiring connections are suitable, replace flame motor. Service Manual Reference Page 12 Problem Flame not bright, flame not visible. Probable Cause Loose wiring or burnt out light bulb(s). Solution Check all wiring for loose connections, repair/replace as necessary.
SYMPHONY ELECTRIC FIREPLACE TROUBLE SHOOTING GUIDE APPEARANCE Problem Fireplace does not turn on. Probable Cause Defective main power on/off switch or loose wiring. Solution Check all wiring for loose wiring connections, repair/replace as necessary. If all wiring connections are suitable check the main on/off switch for proper operation. Replace switch as necessary.
SYMPHONY ELECTRIC FIREPLACE TROUBLE SHOOTING GUIDE HEATER ASSEMBLY Problem Heating element is glowing red. Probable Cause Normal operation or defective heating assembly. Solution Small glowing sections of the element are considered normal. If larger glowing sections are causing the heater to trip the thermal cut out, unplug, discontinue use and replace the heater assembly. Service Manual Reference Page 16 Problem Heater is not turning on.
SYMPHONY ELECTRIC FIREPLACE TROUBLE SHOOTING GUIDE HEATER ASSEMBLY Problem Heater is not turning off. Probable Cause Defective switch or loose wiring or defective heater assembly. Solution Check all wiring for loose wiring connections, repair/replace as necessary. If all wiring connections are suitable check heater on/off switch & heater assembly for proper operation. Replace as necessary.
SYMPHONY ELECTRIC FIREPLACE TROUBLE SHOOTING GUIDE NOISE Problem Excessive noise with the heater on. Probable Cause Excessively dirty blower or defective heater assembly. Solution Remove the top cover and clean the dust out of the blower, if noise persists replace heater assembly or see below. Service Manual Reference Page 16 Problem Grinding or excessive noise with the heater off. Probable Cause Defective flame motor. Solution Replace flame motor with a new one.
SYMPHONY ELECTRIC FIREPLACE TROUBLE SHOOTING GUIDE GENERAL Problem Circuit breaker trips or fuse blows when the unit is turned on. Probable Cause Improper circuit current rating. Solution Additional appliances may exceed the current rating of the circuit breaker or fuse. Plug the unit into another outlet or install on a dedicated circuit with a 15 amp rating. If the unit continues to trip circuit breakers or blow fuses check all wiring for loose connections, repair/replace as necessary.
1367 Industrial Road Cambridge ON Canada N1R 7G8 1-888-346-7539 www.dimplex.com In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice.