13 Device Information
Device information for brine-to-water heat pumps (heating only)
1 Type and order code SI 8MR SI 10MR SI 12TR SI 14TR SI 16TR SI 20TR
2Design
2.1 Model Reversible Reversible Reversible Reversible Reversible Reversible
2.2 Degree of protection according to EN 60 529 IP20 IP20 IP20 IP20 IP20 IP20
2.3 Installation location Indoors Indoors Indoors Indoors Indoors Indoors
3 Performance data
3.1 Operating temperature limits:
Heating water flow °C Up to 60 Up to 60 Up to 60 Up to 60 Up to 60 Up to 60
Cooling, flow °C +7 to +20 +7 to +20 +7 to +20 +7 to +20 +7 to +20 +7 to +20
Brine (heat source, heating) °C -5 to +25 -5 to +25 -5 to +25 -5 to +25 -5 to +25 -5 to +25
Brine (heat sink, cooling) °C +5 to +25 +5 to +25 +5 to +25 +5 to +25 +5 to +25 +5 to +25
Antifreeze
Monoethyl-
ene glycol
Monoethyl-
ene glycol
Monoethyl-
ene glycol
Monoethyl-
ene glycol
Monoethyl-
ene glycol
Monoethyl-
ene glycol
Minimum brine concentration (-13 °C freezing temperature) 25% 25% 25% 25% 25% 25%
3.2 Temperature spread of heating water (flow/return flow) at B0 / W35K 10.6 9.9 9.9 9.4 9.6 10.7
3.3 Heat output / COP at B-5 / W55
1
kW / ---
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
7.5 / 2.0 9.8 / 2.1 9.8 / 2.1 12.2 / 2.3 14.1 / 2.4 18.7 /2.5
at B0 / W50
1
kW / ---
8.8 / 2.8 11.3 / 2.9 11.3 / 2.9 13.5 / 2.9 16.3 / 3.2 20.4 / 3.1
at B0 / W35
1
kW / ---
9.3 / 4.0 11.6 / 4.1 11.6 / 4.1 13.7 / 4.0 16.4 / 4.0 20.0 / 4.2
3.4 Cooling capacity / COP at B20 / W8 kW / --- 9.9 / 4.6 11.4 / 4.6 11.4 / 4.6 14.1 / 5.0 17.3 / 4.9 21.5 / 4.9
at B20 / W18 kW / --- 12.0 / 54 14.1 / 5.3 14.1 / 5.3 17.4 / 5.9 21.5 / 5.9 26.0 / 5.7
at B10 / W8 kW / --- 9.9 / 5.6 11.6 / 5.7 11.6 / 5.7 14.7 / 6.4 18.0 / 6.4 21.9 / 5.9
at B10 / W18 kW / --- 12.4 / 6.7 14.1 / 6.5 14.1 / 6.5 17.4 / 7.1 21.5 / 7.3 27.7 / 7.1
3.5 Sound power level dB(A) 54 55 56 56 56 56
3.6 Heating water flow with an internal pressure differential of m³/h / Pa 0.75/ 2,300 1.0 / 4,100 1.0 / 4,100 1.3 / 4,850 1.5 / 4,000 1.6 / 3,400
3.7 Brine throughput with an internal pressure differential
(heat source) of m³/h / Pa
2.3 /
25,000
3.0 /
24,000
3.0 /
24,000
3.5 /
17,900
3.8 /
18,400
3.5 /
13,900
3.8 Refrigerant; total filling weight type / kg
R407C /
1.3
R407C /
1.5
R407C /
1.4
R407C /
2.1
R407C /
2.4
R407C /
3.2
4 Dimensions, connections and weight
4.1 Device dimensions without connections
2
H x W x L mm
2. Note that additional space is required for pipe connections, operation and maintenance.
1220 x 640
x 624
1220 x 640
x 624
1220 x 640
x 624
1220 x 640
x 624
1220 x 640
x 624
1220 x 640
x 624
4.2 Device connections to heating system Inch G 1" a G 1" a G 1" a G 1" a G 1" a G 1" a
4.3 Device connections to heat source Inch G 1" a G 1" a G 1" a G 1" a
G 1¼"
external
G 1¼"
external
4.4 Weight of the transportable unit(s) incl. packing kg 162 163 164 166 172 237
5 Electrical Connection
5.1 Nominal voltage; fuse protection V / A 230 / 20 230 / 25 400 / 16 400 / 16 400 / 16 400 / 16
5.2 Nominal power consumption
1
B0 W35 kW
2.3 2.8 2.8 3.41 4.1 4.8
5.3 Starting current with soft starter A 38 38 26 26 30 30
5.4 Nominal current B0 W35 / cos ϕ A / --- 12.5 / 0.8 15.2 / 0.8 4.8 / 0.8 6.2 / 0.8 7.4 / 0.8 11.0 / 0,8
6 Complies with the European safety regulations
3
3. See CE declaration of conformity
33333
7 Additional model features
7.1 Water in device protected against freezing
4
4. The heat circulating pump and the heat pump controller must always be ready for operation.
No No No No No No
7.2 Performance levels 1 1 1 1 1 1
7.3 Controller internal/external Internal Internal Internal Internal Internal Internal