Installation manual

168
7.1.1
Table 7.1: Operator button functions
7.1.1 Attaching the wall-mounted heat pump manager (heating)
The controller is attached to the wall with the 3 screws and
dowels (6 mm) included in the scope of supply. The following
mounting procedure should be used to avoid soiling or damaging
the controller:
Mount the dowels for the upper fastening eye at operator
level.
Screw the screw into the dowel so that the controller can be
hung up.
Hang the controller on the upper fastening eye.
Mark the position of the side fastening eyes.
Remove the controller.
Mount the dowels for the side fastening eyes.
Rehang the controller and tighten the screws.
Fig. 7.2: Dimensions of the wall-mounted heat pump manager (heating)
7.1.2 Temperature sensor (heating controller N1)
Depending on the type of heat pump implemented, the following
temperature sensors are already installed or must be additionally
mounted:
Outside temperature (R1) (see Chap. 7.1.2.3 on p. 169)
Temperature 1st, 2nd and 3rd heating circuit (R2, R5 and
R13)
(see Chap. 7.1.2.4 on p. 169)
Flow temperature (R9), as flow sensor in the case of air-to-
water heat pumps
Outlet temperature of the heat source in the case of brine-to-
water and water-to-water heat pumps
Hot water temperature (R3)
Temperature of regenerative heat accumulator (R13)
The heating controller N1 is available in 2 versions:
Heating controller with integrated display (WPM 2006 plus)
(see Chap. 7.1.2.1 on p. 168)
Heating controller with removable control panel
(WPM 2007 plus) (see Chap. 7.1.2.2 on p. 169)
7.1.2.1 Heating controller with integrated display (WPM 2006 plus)
All temperature sensors to be connected to the heating controller
with integrated display must correspond to the sensor
characteristic curve shown in Fig. 7.4 on p. 169.
Button Standard display (Fig. 7.1 on p. 167) Change of setting
Esc
Activates or deactivates the keyboard block
Acknowledges a fault
Exits the menu and returns to the main display
Returns from a submenu
Exits a setting without saving changes
Operation
Selection of the operating mode
No action
Menu
Jumps to menu
No action
Shifts the heating curve downwards (colder) Scrolls downwards between menu items on one level
Changes a setting in a downward direction
Shifts the heating curve upwards (warmer) Scrolls upwards between menu items on one level
Changes a setting in an upwards direction
No action
Selects a setting in the corresponding menu item
Exits a setting and saves changes
Jumps to a submenu
Temperature [°C]
-20 -15 -10 -5 0 5 10 15 20 25
Standard NTC-2 in kΩ 14.62 11.38 8.94 7.07 5.63 4.52 3.65 2.92 2.43 2.00
Standard NTC-10 in kΩ 67.74 53.39 42.29 33.89 27.28 22.05 17.96 14.86 12.09 10.00