Installation manual
www.dimplex.de 171
Heat Pump Manager 7.2
Table 7.2: Menu structure heat pump manager software version H_H_5x
Preconfiguration Settings Outputs
Operating mode Hot water switch comp2 Ventilator / primary pump
Additional heat exchanger Hot water hysteresis 2. Heat generator 2
1. Heating circuit 1
Domestic hot water parallel heating - DHW
Mixer open - heat generator 2
2. Heating circuit 1 Hot water max. temp. - parallel Mixer closed - heat generator 2
3. Heating circuit 1 Hot water parallel cooling - DHW Mixer OPEN - heating circuit 3
Cooling function active Hot water set temperature Mixer CLOSED - heating circuit 3
Passive cooling function Hot water block Heating pump
Passive cooling function - system design Hot water block Heating pump - heating circuit 1
Domestic hot water preparation Hot water block Heating pump - heating circuit 2
DHW preparation request by Thermal disinfection Mixer OPEN - heating circuit 2
DHW preparation - immersion heater Activation of thermal disinfection Mixer CLOSED - heating circuit 2
Swimming pool preparation Thermal disinfection temperature Auxiliary pump
Low pressure brine - measurement present Thermal disinfection Cooling pump
Low-pressure brine Hot water reset HP maximum Switch room thermostat
Swimming pool Reversing valve cooling
Settings Swimming pool Hot water pump
Time Swimming pool block Time1 ... Time2 Immersion heater
Operation Swimming pool block MO ... SU Swimming pool pump
Operating mode Plant - Pump control
Party mode - number of hours Auxiliary pump for heating Inputs
Vacation mode - number of days Auxiliary pump for cooling Low-pressure switch
Heat pump Auxiliary pump for hot water High-pressure switch
No. of compressors Auxiliary pump for swimming pool Defrost end switch
Operating temp. limit Date Year Day Month Day of week Flow rate monitoring
High press. switch Language Hot gas thermostat
Low pressure Flow temp. limit thermostat
2. Heat generator Operating data Motor protection compressor
HG2 limit value External temperature Motor protection primary pump
HG2 mode of operation Return flow set temp. - 1. Heating circuit 1 Utility block (EVU)
HG2 mixer runtime Return flow temp. - 1. Heating circuit 1 Ext. disable contact
HG2 mixer hysteresis Flow temp. Heat Pump Low-pressure brine controller
Utility block (EVU) Set temp. Heating circuit 2 Dew point monitor
Lim. temp. Utility 3 Minimum temperature - heating circuit 2 Hot water thermostat
HG2 special program Temperature - heating circuit 2 Swimming pool thermostat
HG2 overtemperature bivalent-renewable Set temp. Heating circuit 3
HG2 overtemperature bivalent-renewable Temperature - heating circuit 3 Special functions
1. Heating circuit 1 Heating request Compressor switch
1. HC control via Bivalence level Quick start
1. HC heating curve end point (-20°C) Defrost end sensor Deactivate operating
1. HC fixed-setpoint reg. Return flow set temp.
Temperature cylinder regenerative Start-up
1. HK reference room room set temperature Return temperature - passive cooling System control
1. HC return flow min. temperature Flow temperature - passive cooling System monitoring primary side
1. HC Return flow max. temperature Antifreeze - cool - cooling System monitoring secondary side
1. HC hysteresis return flow set temp. Room temperature 1 set temperature System monitoring hot water pump
1. HC time program lower Room temperature 1 System monitoring mixer
1. HC reduction Humidity room 1 Initial heating prog
1. HC lower - lower value Room temperature 2
Initial heating program maximum temperature
1. HC lower MO ... SU Humidity room 2 Hot water / swimming pool active
1. HC time program raise Cooling request Initial heating
1. HC raise Time1 ... Time2 Hot water set temp. Standard program screed drying
1. HC raise - raise value Hot water temp. Individual program heating-up period
1. HC raise MO ... SU Hot water request Individual program maintaining time
2. Heating circuit/heating circuit 3 Swimming pool request Individual program heating-down period
HC 2/3 control via Flow temperature limit sensor Individual program diff. temp.- heating-up
HC 2/3 temperature sensor Coding
Individual program diff. temp. - heating down
HC 2/3 heating curve end point (-20°C) Heating software Individual program screed drying
HC 2/3 colder/warmer Cooling software Measurement temperature difference
HC 2/3 fixed-setpoint Set temp. Network heating / cooling Measure monitor defrost
HC 2/3 return flow maximum value Service
HC 2/3 mixer hysteresis History After-sales service for defrost
HC 2/3 mixer runtime Compressor 1 runtime After-sales service for hot gas defrost
HC 2/3 time program reduction Compressor 2 runtime AE special function
HC 2/3 lower 2. HG2 runtime DA special function
HC 2/3 lower value reduction Primary pump runtime DE special function
HC 2/3 reduction MO ... SU Ventilator runtime AEK special function
HC 2/3 time program raise Heating pump runtime DK special function
HC2/3 raise Time1 ... Time2 Cooling runtime DHW special function
HC 2/3 raise - raise value Hot water pump runtime External temperature sensor
HC 2/3 raise MO ... SU Swimming pool pump runtime Display test
Cooling Immersion heater runtime Performance levels K
Cooling - dynamic cooling Alarm memory No. 2
Dynamic cooling setpoint (ret.) Alarm memory No.1 Modem
Cooling - silent cooling Initial heating begin / end Baud rate
Silent cooling - number room stations Screed drying begin / end Address
Silent cooling setpoint (room temp.) Protocol
Silent cooling dew point distance Outputs Password
2. Chiller 2 Compressor 1 Phone number
Cooling temperature limit Compressor 2 Dialling method
Domestic hot water Four-way valve Number of rings until call answered
Manual dialling