Installation manual

www.dimplex.de 181
Integration of the Heat Pump in the Heating System 8.5.3
Table 8.4: Technical data of the buffer tank
Fig. 8.10: Dimensions of the floor-mounted buffer tank PSW 100 (see also Table 8.4 on p. 181)
Fig. 8.11: Dimensions of the PSP 100E built-under buffer tank for the compact brine-to-water heat pump (see also Table 8.4 on p. 181)
Dimensions and weights Unit PSW 100 PSP 100E PSP 140E PSW 200 PSW 500
Nominal volume l 100 100 140 200 500
Diameter mm 512 600 700
Height mm 850 550 600 1300 1950
Width mm 650 750
Depth mm 653 850
Heating water return flow Inch
1“ internal
thread
1¼“ external
thread
1“ external
thread
1¼“ internal
thread
2 x 2½“
Heating water flow Inch
1“ internal
thread
1¼“ external
thread
1“ external
thread
1¼“ internal
thread
2 x 2½“
Permissible operating overpressure Bar 3 3 3 3 3
Maximum tank temperature °C 95 95 95 95 95
Supporting feet (adjustable) Item 4 3 3
Heating element inserts (1 ½“ internal
thread)
Number21233
Max. heat output per heating element kW 4,5 7,5 9 6 7,5
DN 180 flange Number 1
Weight kg 55 54 72 60 115