8.12.2
8.12.2 Monovalent brine-to-water heat pump
A heating circuit with overflow valve
Preconfiguration Setting
Fig. 8.21: Integration diagram for monovalent heat pump operation with one heating circuit and buffer tank connected in series
(a minimum buffer tank volume of 10 % of the minimum throughput must be ensured either by a buffer tank
connected in series or other suitable measures see Chap. 8.5 on p. 180)
Operating mode
Monoval
ent
1. Heating circuit 1 Yes
2. Heating circuit 1 No
Cooling function
passive
No
Hot water
preparation
No
Swimming pool
preparation
No
In systems which are not
equipped with controllers in the
individual rooms (TC), the
overflow valve must be adjusted
- in combination with an
unregulated heating pump (M13)
- so that the minimum heating
water flow rate is ensured for all
possible operating conditions.
The buffer tank connected in
series increases the circulated
volume and guarantees the
minimum runtimes required by
the compressor when only
individual rooms require heating
(for example, the bathroom).
Two heating circuits with differential pressureless manifold
Preconfiguration
Setting
Fig. 8.22: Integration diagram for monovalent heat pump operation with two heating circuits, one buffer tank connected in
series and hot water heating
Operating mode
Monova
lent
1. Heating circuit 1 Yes
2. Heating circuit 1 Yes
3. Heating circuit 1 No
Cooling function
passive
No
Hot water
preparation
Yes
Request Sensors
Flange heater Yes
Swimming pool
preparation
No
If there is more than one heating
circuit, the generator and
consumer circuits must be
hydraulically isolated.
The differential pressureless
manifold ensures the heating
water flow and must have the
same cross section as the flow
and return lines.
1%
7

5
11
0
11
(
1%
5
11
0
1%
5
111
00$0=
11
0
::0
00+
::0
97%
7
7
7&
7&
0
1

0
11
(%.39
97%
7
1%
5
11
0
.39