Installation manual
www.dimplex.de 211
Help with Planning and Installation 10.3
10.3 Minimum Requirements for Domestic Hot Water Cylinder / Circulating
Pump
Air-to-water heat pump for indoor installation
Air-to-water heat pump for outdoor installation
Brine-to-water heat pump for indoor installation
Water-to-water heat pump for indoor installation
(On the basis of the integration set-ups recommended in this
manual and standard boundary conditions)
The table shows which domestic hot water circulating pumps and
cylinders should be allocated to each type of heat pump in order
to obtain a hot water temperature of approx. 45 °C in operation
with 1 compressor (maximum temperature of the heat source:
Air: 25 °C, brine: 10 °C, water 10 °C).
The maximum hot water temperature which can be attained with
heat-pump-only operation is dependent on:
The heat output of the heat pump
The heat exchanger surface area in the cylinder
The volume flow in relation to the pressure drop and the
capacity of the circulating pump.
NOTE
Higher temperatures can be reached by implementing larger heat
exchanger areas in the cylinder, by increasing the volume flow or by
targeted reheating using a heating element (see also Chap. 6.1.3 on p.
149).
Heat Pump Volume Order designation Pump
LIK 8TE / LI 9TE / LI 11TE / LI 20TE
LIK 8ME / LI 11ME
300 l WWSP 332 / PWS 332 UP 60
LI 24TE 400 l WWSP 880 UP 60
LI 16TE / LI 28TE
LIH 22TE
400 l WWSP 880 UP 80
LIH 26TE 500 l WWSP 900 UP 80
Heat Pump Volume Order designation Pump
LA 11AS / LA 20AS
LA 9PS / LA 11PS / LA 17PS
LA 11MS
300 l WWSP 332 / PWS 332 UP 60
LA 22PS 300 l WWSP 332 / PWS 332 UP 80
LA 24AS 400 l WWSP 880 UP 60
LA 16AS / LA 28AS
LA 26PS / LA 22HS
LA 16MS
400 l WWSP 880 UP 80
LA 26HS 500 l WWSP 900 UP 80
Heat Pump Volume Order designation Pump
SIK 7TE / SIK 9TE / SIK 11TE
SI 5TE / SI 7TE / SI 9TE / SI 11TE
SIK 11ME / SI 5ME / SI 9ME / SI 11ME
300 l WWSP 332 / PWS 332 UP 60
SIK 7TE / SIK 9TE / SIK 11TE / SIK 11ME 400 l WWSP 442E UP 60
SIK 14TE / SIK 16ME 400 l WWSP 442E UP 80
SI 14TE / SI 17TE 400 l WWSP 880 UP 80
SI 21TE 500 l WWSP 900 UP 80
SIH 20TE / SI 24TE 400l WWSP 442E UP 32-70
SIH 40TE / SI 37TE 500l WWSP 900 UP 32-70
SI 50TE 500 l WWSP 900
4.5 m
3
/h
SI 75TE 2 x 400 l 2 x WWSP 880
6.5 m
3
/h
SI 100TE 2 x 500 2 x WWSP 900
8.5 m
3
/h
SI 130TE 3 x 500 3 x WWSP 900
11.5 m
3
/h
Heat Pump Volume Order designation Pump
WI 9TE / WI 14TE 300 l WWSP 332 / PWS 332 UP 60
WI 18TE / WI 22TE 400 l WWSP 880 UP 80
WI 22TE 500 l WWSP 900 UP 60
WI 27TE 500 l WWSP 900 UP 80
WI 40CG 500 l WWSP 900 UP 80
WI 90CG 2 x 500 l 2 x WWSP 900
8 m
3
/h