Installation manual
58
2.11.1
Installation on a wall
Important information:
For an installation set-up without an air duct, it is imperative
that the interior side of the wall opening is lined with thermal
insulation to prevent the wall from becoming cold and to
prevent moisture from penetrating the wall (e.g. 50 mm rigid
polyurethane foam/aluminium foil).
Legend:
1) Standard polyurethane foam
2) Sealing collar
3) Air duct
4) Bevel for sealing the edges and improving the air circuit
* The dimensions must be increased correspondingly when an
insulating strip is used.