Brine-to-Water Heat Pump 3.6.1
3.6 Device Information for Brine-to-Water Heat Pumps (3-Phase, 400V AC)
3.6.1 Low-temperature heat pumps in a compact design SIK 7TE to SIK 14TE
Device information for brine-to-water heat pumps for heating purposes
1 Type and order code
SIK 7TE SIK 9TE SIK 11TE SIK 14TE
2Design
2.1 Design Compact Compact Compact Compact
2.2 Degree of protection according to EN 60 529 IP20 IP20 IP20 IP20
2.3 Installation location Indoors Indoors Indoors Indoors
3 Performance data
3.1 Operating temperature limits:
Heating water flow °C Up to 58 Up to 58 Up to 58 Up to 58
Brine (heat source) °C -5 to +25 -5 to +25 -5 to +25 -5 to +25
Antifreeze
Monoethylene
glycol
Monoethylene
glycol
Monoethylene
glycol
Monoethylene
glycol
Minimum brine concentration (-13 °C freezing temperature) 25% 25% 25% 25%
3.2 Temperature spread of heating water (flow/return flow) at B0 / W35K 9.9 5.0 10.5 5.0 10.1 5.0 9.6 5.0
Heat output / COP at B-5 / W55
1
kW / ---
1. This data indicates the size and capacity of the system according to EN 255 or EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point
and regulation should be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow
temperature 55 °C.
5.6 /
2.2
7.7 /
2.3
9.4 /
2.4
12.5 /
2.6
at B0 / W45
1
kW / ---
6.6 /
3.0
8.7 /
3.2
11.2 /
3.2
14.1 /
3.5
at B0 / W50
1
kW / ---
6.7 /
2.9
9.0 /
3.1
11.3 /
3.0
14.2 /
3.4
at B0 / W35
1
kW / ---
6.9 /
4.3
6.8 /
4.1
9.2 /
4.4
9.0 /
4.2
11.8 /
4.4
11.7 /
4.2
14.5 /
4.5
14.4 /
4.3
3.3 Sound power level dB(A) 51 51 51 51
3.4 Heating water flow with an internal pressure differential of m³/h / Pa
0.6 /
2500
1.2 /
11600
0.75 /
4500
1.6 /
20500
1.0 /
3500
2.0 /
14800
1.3 /
3500
2.5 /
16500
3.5 Free compression of heat circulating pump (level 3) Pa 47500 30400 43500 18500 65500 48200 64500 42500
3.6 Brine flow with an internal pressure differential (heat source) of m³/h / Pa
1.7 /
10000
1.6 /
9300
2.3 /
16000
2.2 /
15000
3.0 /
13000
2.7 /
11400
3.5 /
13000
3.3 /
11600
3.7 Free compression of brine circulating pump (level 3) Pa 55000 56200 44000 46000 40000 44600 34000 38400
3.8 Refrigerant; total filling weight type / kg R407C / 1.5 R407C / 1.8 R407C / 2.0 R407C / 2.3
4 Dimensions, connections and weight
4.1 Device dimensions without connections
2
H x W x L mm
2. Note that additional space is required for pipe connections, operation and maintenance.
1115 × 652 × 688 1115 × 652 × 688 1115 × 652 × 688 1115 × 652 × 688
4.2 Device connections to heating system Inch R 1¼" external R 1¼" external R 1¼" external R 1¼" external
4.3 Device connections to heat source Inch R 1¼" external R 1¼" external R 1¼" external R 1¼" external
4.4 Weight of the transportable unit(s) incl. packing kg 179 180 191 203
5 Electrical connection
5.1 Nominal voltage; fuse protection V / A 400 / 16 400 / 16 400 / 16 400 / 16
5.2 Nominal power consumption
1
B0 W35 kW
1.6 1.662.072.142.662.793.223.37
5.3 Starting current with soft starter A 30 (without SS) 15 26 26
5.4 Nominal current B0 W35 / cos ϕ A / ---
2.89 /
0.8
3 /
0.8
3.77 /
0.8
3.86 /
0.8
4.84 /
0.8
5.03 /
0.8
5.81 /
0.8
6.08 /
0.8
6 Complies with the European safety regulations
3
3. See CE declaration of conformity
3 3 3
7 Additional model features
7.1 Water in device protected against freezing
4
4. The heat circulating pump and the heat pump controller must always be ready for operation.
Yes Yes Yes Yes
7.2 Performance levels 1111
7.3 Controller internal/external Internal Internal Internal Internal