Operating instructions

57
730.138 | 08.12
EN
8.1 Status display
Switching the display screen
: press button.
The following values and displays appear one after another:
The temperature sensors of the system set, and the corresponding
current temperature values.
Outputs and corresponding running times.
Functions, and their additional measured values.
The additionally set functions are displayed.
8.2 Temperature sensor min/max display
Display of the min/max values
: choose the desired temperature sensor.
SET: access the information window.
The min/max values are displayed.
Resetting the min/max values
SET: press button for approx. 2 sec.
The min/max values are reset to the current temperature.
NOTE
The minimum and maximum values of the connected temperature sen-
sors are always logged and accessible.
The values stored can be reset at any time.
8.3 Operating hours display for pumps
switching valves
Display of the operating hours
: choose the desired pump or valve.
SET: access the information window.
The hours-of-operation logger is displayed.
Resetting the operating hours
Operating hours called up.
SET: press button for approx. 2 sec.
The delta value (∆) is reset to zero.
The outputs' operating hours are always stored.
Here, a distinction is made between total operating hours (∑) and delta
operating hours (∆). The total operating hours cannot be reset. How-
ever, delta operating hours can be reset to zero at any time.
K
Sample display
K
Sample display
PD[
PLQ
&
&
VHF
6(7
Sample display
PD[
PLQ
&
&
VHF
6(7
Sample display
¨
K
VHF
K
6(7
Sample display
¨
K
VHF
K
6(7
Sample display