Operating instructions
72
730.138 | 08.12
EN
Heat quantity:
Factory
setting
Adjustable
down to
min.
Adjustable
up to max.
Comment
Pulse value for recording flow rate with a pulse generator:
1 l/Imp 25 l/Imp, 10 l/Imp, 1 l/Imp, 10 Imp/l, 20 Imp/l, 50 Imp/l, 100 Imp/l, 200 Imp/l, 300 Imp/
l, 400 Imp/l, 500 Imp/l, 600 Imp/l, 700 Imp/l, 800 Imp/l, 900 Imp/l, 1000 Imp/l
Recording flow rate with Grundfos sensor type (Direct Sensor):
-- VFS 1 - 20, VFS 2 - 40, VFS 5 - 100, VFS 10 - 200
Glycol content:
40 % 0 % 60 %
Flow rate value for recording flow rate without a flow sensor:
Flow rate value for maximum pump speed:
-- 0 99 The flow rate value for the maximum pump speed
must be greater than the flow rate value for the
minimum pump speed.
Flow rate value for minimum pump speed:
-- 0 99 The flow rate value for the maximum pump speed
must be greater than the flow rate value for the
minimum pump speed.
Thermostat:
Factory
setting
Adjustable
down to
min.
Adjustable
up to max.
Comment
Temperature controlled:
Switch-on temperature:
20 °C
0 °C 180 °C The on and off values can be set independently of
each other.
Switch-off temperature:
20 °C 0 °C 180 °C
Time controlled:
-- 00.00 23.59 Programming a time period which goes beyond
midnight (24.00) is not possible.