SV8000 Professional steam & vacuum cleaning machine User instructions Warning Do not operate this appliance before reading and understanding these instructions. Always keep the instructions attached to the appliance or readily available at the appliance storage site.
Technical specification Congratulations Boiler capacity (continuous fill) 3.3 litres Water tank capacity 5 litres Chemical tank capacity 2.
Warnings This machine has been designed with your safety in mind, however it is important that you observe the following points for safe operation • To obtain best results from your steam cleaner please read the instructions carefully. • This appliance is for indoor use only. • If the electrical cable becomes damaged the complete cable must be replaced. Do not attempt this task yourself contact the supplier of this product. • If the Hose Assembly becomes damaged the complete assembly must be replaced.
Components ⁄ ¤ ‹ › fi fl ‡ · ‚ „ ‰ Â Ê Á Ë Solution tank connection point Cold water tank Steam control Vacuum control On/Off switch Mode switch Collection tank Temperature display LED Pressure gauge Vacuum hose connection Steam hose connection Castors with brake Accessory basket Rating label Filter panel A ⁄ ¤ ‡ ‹ › fi fl · ‚ Ê „ ‰ Á Ë Â B fl fi 170 4
Accessories È Í Î Ï Ì Ó Ô Ò Ú Û Ù 2 x extension tubes Floor tool Floor squeegee 400mm Carpet strip 400mm Floor brush 400mm Detail nylon brush Detail wire brush Window squeegee Steam lance short Steam lance long Upholstery tool 4m hose complete with handle controls C Ú Í È Ò Î Ï Ì Ó Ô Ù Û 5
Steam vacuum operating procedure 1 Switch mode switch fl to position II. • Mode 2 switches on the boiler heater and enables the handle control (i.e. steam, vacuum and detergent switches). 2 Remove the top cover of the collection tank ‡ and pour clean cold water into the tank up to the white mark (approx 1 litre). 3 Replace top cover on the collection tank. 4 Fill the Cold water tank ¤ with clean water. 5 Connect the Solution tank hose to the chemical point ⁄ on top of the machine if required.
3 Switch off the machine, empty the collection tank and rinse clean 4 Pour cold water in to the collection tank to fill up to the white mark and recommence cleaning. Maintenance Warning: Disconnect machine from the mains before cleaning or maintenance. Daily maintenance To be carried out every day or every 10 hours of operation. 1 Wash the hose by sucking one or two litres of water from a basin into the recovery tank. 2 Unplug the machine and wipe down with a clean cloth.
5 When cleaning carpet fit the carpet cleaning insert. 6 When cleaning Altro or vinyl floors fit the squeegee insert. 7 Steam and vacuum the floor by following the machine operating instructions. Service Detailed cleaning In Ireland Outside Ireland 1 Fit the detail nozzle to the handle locking it in place. 2 Fit the round plastic bristle brush to the detail nozzle. 3 After cleaning fit the floor tool and vacuum away the liquid. Safety precautions This machine is to be used by trained operatives only.
Troubleshooting Symptom Possible Cause Action No power Not connected / Faulty socket Check connection to wall socket and socket switch.
Clash Industrial Estate Tralee Co. Kerry Ireland T 00353 66 7121444 F 00353 66 7193380 E sales@dimplexcleaning.com W www.dimplexcleaning.