Technical data
77..00 SSIITTEE RREEQQUUIIRREEMMEENNTTSS
77..11 LLOOCCAATTIIOONN
1. The boiler may be fitted to any suitable wall with the flue
passing through an outside wall or roof and discharging to
atmosphere in a position permitting satisfactory removal of
combustion products and providing an adequate air supply. The
boiler should be fitted within the building unless otherwise
protected by a suitable enclosure i.e. garage or outhouse. (The
boiler may be fitted inside an unvented cupboard - see section
7.3).
2. If the boiler is fitted in a room containing a bath or shower
reference must be made to the relevant requirements.
In GB this is the current I.E.E. Wiring Regulations and Building
R
egulations.
In IE reference should be made to the current edition of I.S.
813 “Domestic Gas Installations” and current ETCI rules.
(Fig. 11 shows zone dimensions for a bathtub. For other
examples refer to Section 601 of the current I.E.E. Wiring
Regulations) reference must be made to the relevant
requirements.
The boiler is IPX4 rated and can be fitted in Zone 2 (Fig. 11).
3. If the boiler
is to be fitted into a building of timber frame
construction then reference must be made to the current
edition of Institute of Gas Engineers Publication IGE/UP/7 (Gas
Installations in Timber Framed Housing).
© Dimple
x Boiler
s 2008
1133
77..22 CCLLEEAARRAANNCCEESS
1. A flat vertical area is required for the installation of the
boiler.
2. These dimensions include the necessary clearance around
the boiler for case removal, spanner access and air movement.
Additional clearances may be required for the passage of pipes
around local obstructions such as joists running parallel to the
f
r
ont face of the boiler.
Zone 2
Zone 2
Zone 1
Zone 0
Zone 3
Zone 3
Window Recess
Zone 2
Window
Recess
Zone 2
0.6 m 2.4 m
Zone 2 Zone 3
Zone 2Zone 1
Zone 0
Zone 3
Outside Zones
Ceiling
Window
Recess
Zone 2
3.0 m
2.25 m
0.6 m 2.4 m
285mm Wall
450mm Min
For Servicing
Purposes
5mm Min
In Operation
5mm Min
446mm
5mm Min
796mm
200mm
200mm
5mm Min
5mm Min
285mm Wall
285mm Wall
FFiigg.. 1111
FFiigg.. 1122