Technical data

77..00 SSIITTEE RREEQQUUIIRREEMMEENNTTSS
77..66 CCOONNDDEENNSSAATTEE DDRRAAIINN
NNOOTTEE::
The appliance is fitted with a trap the depth of
which is >= 75mm, therefore no other traps are required in
the condensate run.
The condensation discharge pipe must not rise at any point
along its length. There MUST be a fall of AT LEAST 2.5° (50mm
per metre) along the entire run.
1. The condensate outlet will accept 21.5mm (
3
/
4
in) plastic
overflow pipe which should discharge internally into the
household drainage system, downstream of all other traps. if
this is not possible, discharge into an outside drain is
ac
ceptable.
2. Ensure the discharge of condensate complies with any
national or local regulations in force.
BBSS 66779988::22000000 && PPaarrtt HHII ooff tthhee BBuuiillddiinngg RReegguullaattiioonnss ggiivvee
ffuurrtthheerr gguuiiddaannccee..
3. Metal pipework is NOT suitable for use in condensate
discharge systems.
4. The pipe should be a minimum of 21.5mm diameter and
must be supported properly.
5.
IItt iiss aaddvviissaabbllee ttoo kkeeeepp tthhee ccoonnddeennssaattee ppiippee iinntteerrnnaall..
6.
EExxtteerrnnaall rruunnss ggrreeaatteerr tthhaann 33 mmeettrreess oorr rruunnss iinn ccoolldd aarreeaass
sshhoouulldd uussee 3322mmmm wwaassttee ppiippee aanndd bbee iinnssuullaatteedd..
7. If the boiler is fitted in an unheated location the entire
condensate discharge pipe should be treated as an external
run.
8. In all cases discharge pipe must be installed to aid disposal
of the condensate.
9. When discharging condensate into a soil stack or waste pipe
the effects of existing plumbing must be considered. If soil
pipes or waste pipes are subjected to internal pressure
fluctuations when WC’s are flushed or sinks emptied then
back-pressure may force water out of the boiler trap and
cause appliance lockout.
Ex
amples ar
e shown of the
f
ollowing methods of terminations
(se
e figs. 14,15 & 16):
i) to an internal soil & vent pipe
ii) via and internal discharge branch (e.g. sink waste)
iii) to a drain or gully
i
v) to a purpose made soakaway
10. In e
x
ceptional circumstances, such as when a boiler is
installed in a basement without drainage, it may be necessary
t
o ins
t
all a condensate pump to carry condensate up to ground/
d
r
ain le
v
el. Such pr
oducts ar
e a
v
ail
able
from most plumbing
merchants. For help with selecting a condensate pump contact
Dimplex Boilers - Tel: 0844 3711121.
WWAARRNNIINNGG::
There must be no air breaks in the condensate
pipework or drainage system (see Fig. 17).
© Dimple
x Boiler
s 2008
1155
5
0
mm p
e
r me
tre
o
f p
ip
e
r
u
n
2.5° Minimum fall
4
50mm min
T
ermination to an internal soil and vent pipe
50mm per metre of pipe r
un
2.5° Minimum fall
External termination via internal discharge branch
e
.g sink waste - downstream
Sink
Pipe must terminate
above water level but
below surrounding surface.
50mm per metre of pipe r
un
2.5° Minimum fall
Termination to a purpose made soak-away
Holes in the soak-away must
face away from the building
500mm min
NNOOTT AALLLLOOWWEEDD
T
T
h
h
e
e
r
r
e
e
s
s
h
h
o
o
u
u
l
l
d
d
b
b
e
e
n
n
o
o
a
a
i
i
r
r
g
g
a
a
p
p
FFiigg.. 1144
FFiigg.. 1155
FFiigg.. 1177
FFiigg.. 1166