The different flue applications shown in Fig. 20 are available as
kits comprising the connecting parts to the appliance and end
terminal. Flue extension ducts and extension elbows are
available as accessories.
88..22 KKiitt AA ++ TTeelleessccooppiicc HHoorriizzoonnttaall WWaallll TTeerrmmiinnaall
((CC1133)) -- PPaarrtt NNoo.. 995566112200
60/100mm concentric, horizontal flue system Fig. 21, with a
maximum length of 10M.
The standard telescopic terminal is 615mm max length and
430mm min length, but can be cut to a minimum flue length of
250mm, which is suitable for single, 100mm (4”), brick walls.
NNoottee::
If the telescopic flue kit is installed without any flue
extensions, it can be fitted horizontally. The maximum
length for 60/100mm horizontal concentric flue = 10M
NNoottee::
Dimplex System 18 only, with maximum concentric
flue length of 10m, the heat input will be reduced by 7.6%
88..33 KKiitt BB VVeerrttiiccaall CCoonncceennttrriicc FFlluuee TTeerrmmiinnaall
((CC3333)) -- HHBBLL PPaarrtt 995566008811
60/100mm concentric, vertical flue system, Fig. 22, with a
maximum length of 12M.
The kit comprises of the roof terminal, vertical adaptor with
sampling point and bracket.
The ma
ximum length i
s me
asur
ed
f
rom the top of the
appliance casing to the underside of the air cowl.
For installation details refer to the flue kit instructions.
Chimney flue liner kit
- Part no. 956082
Vertical flue kit - Part no. 956081
V
ertical flue kit - Part no. 956081
with flat roof flashing plate
Split pipe vertical flue outlet kit
- Part no. 956080
with flat roof flashing plate
Raised external flue outlet kit
- Part no. 956084
Vertical flue kit - Part no. 956081
External vertical flue kit
- Part no. 956085
S
tandard telescopic
horizontal flue kit
- Part no. 956120
O
ptional Flue Systems
The pluming from the flue may
cause nuisance to neighbours
or other buildings.
60/100 flue accessories:
0.5m flue extension duct - 956092
1m flue extension duct - 956093
9
3 flue extension elbow - 956091
4
5 flue extension elbow (2x) - 956090
Vertical flue turret - 956087
Ø60/100mm concentric
standard horizontal wall
terminal.
M
ax. length 10,000mm.
M
in. length 250mm.
Standard telescopic horizontal flue kit - Part no. 956120
H
orizontal terminal has a
built-in fall in the flue to allow
condensate to drain away.
If horizontal flue requires
extension pipe. the flue
should be installed such
that there is no section less than
1
.5° - 3° to the horizontal,
falling back towards the boiler.
9
3 flanged elbow (concentric)
with sampling point
Kit A +
Vertical flue kit - Part no. 956081
Suitable for 25 - 45°
Pitch Angle
Length
Kit B
60/100 flue accessories:
0.5m flue extension duct - 956092
1m flue extension duct - 956093
93 flue extension elbow - 956091
45 flue extension elbow (2x) - 956090
Pitched roof flashing kit - 956089
Flat roof flashing plate - 840512
93 flanged flue elbow - 956086
Max. length12m.
Min. length 0.6m.
Roof terminal
with rain cover
and pitched roof
flashing kit.
Vertical flue socket
with sampling point.
Top of Boiler
to underside of Cowl
FFiigg.. 2200
FFiigg.. 2211